V
10/04
OptiGun 2-A(X) (GA02) Automatic powder gun
Start-up
•
21
Start-up
Connecting the OptiGun 2-A(X) Automatic powder gun
1. Connect the gun plug to gun control unit (see the OptiTronic con-
trol unit operating instructions)
2. Connect the rinsing air hose of the control unit to the gun
3. Connect the powder hose from the gun to injector
Input 24 VDC
Aux
Gun 1
1.1 IN
5 bar
73 PSI
2.1
2.4
1.3
1.4
1.5
2.3
Gun 2
2.2
1.2
OptiTronic
F1
2,0 AT
Aux
2.5
Connecting the OptiGun 2-A(X) Automatic powder gun
1
Rinsing air hose
4
Supplementary air hose
2
Powder hose
5
Conveying air hose
3
Powder gun cable
6
Injector
Function check
General information
1. The installed gun must be directed toward a grounded work-
piece in the coating booth. All connections must be attached!
2. Switch on the gun control unit (see also the control unit operat-
ing instructions) - the gun starts spraying
3. Adjust the desired coating parameters (powder volume, total air
and high voltage) on the gun control unit (see also the control
unit operating instructions)
4. Adjust the rinsing air on the control unit dependent upon the
nozzle used
1
6
5
4
2
3