Integrated Technical Vision Ltd.
45
Switch to the standalone mode
To switch into the standalone mode, proceed:
1.
Depower panel
2.
Remove the top cover of panel, leaving connected cable running to the
bottom board
3.
Short ALM and DC terminals
4.
Power up panel
5.
Wait for tree short and one long beep, signaling the successful panel switch
into the standalone mode
6.
Depower panel and remove short from ALM and DC terminals
Switch to the in system mode
To switch into the in system mode, proceed:
1.
Depower panel
2.
Remove the top cover of panel, leaving connected cable running to the
bottom board
3.
Short ALM and RTE terminals
4.
Power up panel
5.
Wait for tree short long beeps, signaling the successful panel switch into the
standalone mode
6.
Depower panel and remove short from ALM and RTE terminals
Factory settings
Mode - standalone
Master code
– 1234
Engineers code - 5678
Entry/exit duration
– 20 seconds,
Code matching blocking duration
– 40 seconds
Inputs: RTE
– ‘day and night’ mode, EIN - disabled
Outputs: Relay #1
– 3 seconds, Relay #2 – 3 seconds, ALM (alarm) – 10 seconds
Readers: full code read (42bit), ASK.