SERVICE MANUAL
SPIKA SERIES
20
t3
Open curtain time to activate full storage indication
30”
t4
Start-up timing time
30”
t5
Harvest maximum time
180”
t6
Draining time during operation launching
2
0”
t7
Production minimum time
120’’
t8
Water inlet valve e/w time during production
30”
t9
Water inlet valve e/w timeout
180”
t10
Production maximum timeout
3600’’
t11
Pump start-up delay time
30”
t12
Draining time at cleaning cycle
60”
t13
Retry time due to water inlet valve e/w timeout
3600’’
t14
Upper unit change
60’’
t15
Maximum time to reset due to security pressure switch
600’’
5.2.-MS CONTROL BOARD
PCB connections
Outputs
C
compressor
B
Water pump
EW
Water inlet valve
GC
Hot gas valve.
EP
Drain valve
SL
Free
Inputs
ICE
Ice position switch
WASH
Wash position switch
P
Safety pressure switch / NC contact
MC
Curtain micro relay contact NC