SCALA ICE MACHINE MAINTENANCE
completely drained.
10.
Once the unit is drained, close the drainage faucet and open the inlet water faucet.
11.
Before connection the unit, please reconnect the cold production. To do so access the electric
box again and connect the cable to the terminal #6.
12.
Connect the unit to the electricity. Produce ice for 5 minutes.
CAUTION: Discard the ice produced during this time.
13.
After this time the unit can be used normally.
Exterior cleaning
1.
Disconnect the unitfrom electricity and close the water inlet.
2.
Use a cloth with a degreasing detergent.
3.
Apply 3 in 1 on the surface to leave a protective film.
8.
MAINTENANCE TABLE:
MAINTENANCE TASK
Dusty environment
Normal
environment
Saline environment
Air condenser cleaning
6 months
12 months
6 months
Cleaning inside evaporator.
6 months
6 months
3 months
MAINTENANCE TASK
Agua dura (mayor
400ppm)
Agua normal (menor
400ppm)
Brine
Water filter replacement
6 months
12 months
6 months
Hydraulic circuit cleaning
6 months
12 months
Rinse with mains water after each
prolonged shutdown (+12h).
Exterior cleaning
6 months
12 months
6 months
Sanitary cleaning
6 months
6 months
6 months
Evaporator interior cleaning.
3 months
6 months
3 months