This manual covers installation, programming and utilization of  NDC-B052
access control panel. Read this manual carefully prior to installing and program-
ming the unit.

Design Change Disclaimer

Information due to design changes and product improvements in this manual is
the subject to change without notice. ITV reserves the right to change the
product design any time, that will subsequently affect the contents of this
manual.
ITV assumes no responsibility for any mistakes that can appear in the manual.
The company guarantees that this Installation Manual is up to date and
corresponds with the unit you purchase.

Reproduction Disclaimer

All rights to this document are preserved by Integrated Technical Vision Ltd.
Copying, printing and any other kind of unauthorised reproduction of this
document or a part of it is prohibited.

Trademarks

ITV®  is a registed trademark of Integrated Technical Vision Ltd.

Training and technical support

Integrated Technical Vision Ltd performs training on the installation, program-
ming and utilisation of  NDC-B052 access control panel. For detailed information
about training and discussing of your particular requirements to the unit please
contact our personnel  by the phone numbers below.
It is recommended, for the staff intended for sales and installation of NDC-B052
access control panel to take instruction courses conducted by the company.
Technical support for all  products of Integrated Technical Vision Ltd can be
obtained at business time by the phones below:
+380(0)44 248 65 88
+380(0)44 248 65 89
+380(0)44 248 65 90
This support assumes the calls of trained specialists. End users must apply to
their dealers or installers before phoning us. This information is available on our
web site www.itvsystems.com.ua

Summary of Contents for NDC-B052

Page 1: ...NDC B052 Access Control Panel Installation Manual NDC B052 A C C E S S C O N T R O L P A N E L ...

Page 2: ...2 Integrated Technical Vision Ltd http www itvsystems com ua ...

Page 3: ...her kind of unauthorised reproduction of this document or a part of it is prohibited Trademarks ITV is a registed trademark of Integrated Technical Vision Ltd Training and technical support Integrated Technical Vision Ltd performs training on the installation program ming and utilisation of NDC B052 access control panel For detailed information about training and discussing of your particular requ...

Page 4: ...4 Integrated Technical Vision Ltd http www itvsystems com ua ...

Page 5: ... Wiring Configurations 12 Controls and connections on board 13 Control Panel Operation 14 Main Mode 14 Alarm Mode 14 Free Pass Mode 15 Blocked Mode 15 Mounting 15 RS 485 Interface 16 RS 232 Interface 17 Ethernet Port 17 Setting id and IP Address 18 Resetting hardware to factory defaults 21 Power Supply Wiring 21 Limited Warranty 22 Index 24 ...

Page 6: ...6 Integrated Technical Vision Ltd http www itvsystems com ua ...

Page 7: ...stems with many access and monitor points The panel can control up to 64 access points All access points are attached to NDC B052 via expansion modules using RS485 bus Up to 32 modules can be connected to the control panel Features Supports all Wiegand reader technologies Distributed database for independent operation Operates in remote site configurations with dial up Card PIN or card and PIN acc...

Page 8: ... Operation temperature 0 С 55 С Relative Humidity 80 relative at 35 С Physical dimensions Width 300mm Height 310mm Depth 80mm Weight 2 45 kG Nonerasable memory Identificators up to 20 000 Weekly schedules up to 255 Time zones up to 255 Holidays up to 255 Events up to 80 000 Specifications ...

Page 9: ... Global Antipassback function application Code matching NDC B052 can arise alarm in case of attempt of code or ID matching Code matching is considered when invalid code or ID is entered several times Valid code entrance clears the counter This function switching on and number of code entries can be programmed on PC Door Sensor In access control systems various sensors are used to control door stat...

Page 10: ... RTE button by re energizing locking device opening lock with a key etc the Door Forced Open event arises RTE button may be used for remote door opening as well Schedules NDC B052 is capable to store up to 255 time zones 255 week schedules and 255 holidays Moreover NDC B052 can store several floating schedules based on a period different to a week The number of such floating schedules depends on t...

Page 11: ...iguration The layout of NDC B052 is shown on Diagram1 below 1 battery backup PCB 2 terminal block with safety fuse 3 220V 50Gz transformer 4 panel PCB 5 battery Diagram1 General view of NDC B052 with front cover off 1 2 6 DCG ACG GND 12V 220 V 50 Hz 3 4 General Configuration ...

Page 12: ...12 Integrated Technical Vision Ltd http www itvsystems com ua Ethernet PC or modem Other NDC B052 NTC LNET RS485 RS485 RS232 Wiring Configurations Diagram2 Wiring Configurations ...

Page 13: ...3 and FUSE4 power inputs fuses from alternating current source l a n i m r e T n o i t c n u F n o i t p i r c s e D V 9 V 9 n o i t c e n n o c r e w o p V 9 V 2 1 V 2 1 n o i t c e n n o c r e w o p V 2 1 D N G D N G 5 8 4 S R t s r i F t r o p T U 1 5 8 4 S R 2 1 A 1 A 5 8 4 S R B 1 B 5 8 4 S R D N G D N G d n o c e S 5 8 4 S R t r o p T U 2 5 8 4 S R 2 1 A 2 A 5 8 4 S R B 2 B 5 8 4 S R D N G D...

Page 14: ...it is necessary LED blinks yellow that means PIN entry is awaited After valid PIN entry door is unlocked and reader LED lights green Using RTE To go out of the premises with a single sided door user must depress press release Request to Exit button Reader LED lights green Access Denial Access may be denied by the following reasons Panel is not downloaded reader LED does not light or blink ID is no...

Page 15: ...een and yellow alternately Access point switches into the Free Pass mode with the operator command or if the input programmed as Free Pass is broken Access point is in Free Pass Mode until this input is shorted or the operator cancels the mode While Access point is in Free Pass mode locking device is locked and the panel does not respond to IDs passing PIN entry or RTE button pressing The control ...

Page 16: ...1A 1B con tacts is intended for expansion modules and subordinate panels connection The range of RS 485 bus is up to 1200 meters The number of panels or expansion modules is up to 32 RS 485 port is protected against overvoltage 60V and cross polarization Unshielded four wire cable may be used for RS 485 wiring For maximal range of 1200 meters please use 0 4 mm 2 cross section wire 0 2 mm 2 cross s...

Page 17: ...us receiver transmitter DB9 jack in addition to RS485 bus receiver transmitter NDC B052 access control panel can be connected to PC straight via null modem cable or modem using this output Ethernet Port The NDC B052 access control panel is provided with UTP jack for Ethernet connec tion UDP protocol is supported D C G A C G G N D 1 2V 220 В 50 Гц NDC B052 RS485 RS485 Jumpers are set Mounting ...

Page 18: ...thin 40 seconds the panel switches to the main mode In process of launching LED4 blinks and then switches off Now start ggipcfg exe program Choose Action Search hardware menu items and press button Search of devices will be executed on all COM ports In the bottom part of program window the result of search will be displayed Data exchange between PC and NDC B052 during search will be seen on blinki...

Page 19: ...d If testing of device passed successfully and loading is not executed the message Con figuration is not loaded controller is in operation mode appears which means JP4 crosspiece is not set Set the crosspiece and repeat actions on configuration loading If loading of the controller controllers is executed on the computer where Golden Gate software is not installed it will be necessary to export the...

Page 20: ...ntegrated Technical Vision Ltd http www itvsystems com ua press button transfer obtained reg file to the PC with installed Golden Gate program and execute merge to system registry Setting id and IP Address ...

Page 21: ...The panel switches into unloaded state all settings and tables are deleted After resettling to factory defaults panel s id is set to 0 value Power Supply Wiring PSU 1 5 power supply unit with battery backup manufactured by ITV Ltd use is recommended This power supply unit provides 12V power rated at 1 5A The 7AH battery may be used in it PSU 1 5 has outputs for power and battery status indication ...

Page 22: ...al shock water damage or damage arising out of abuse alteration or improper application of the equipment The foregoing warranty shall apply only to the original buyer and is and shall be lieu of any and all other warranties whether expressed or implied and of all other obligations or liabilities on the part of Integrated Technical Vision Ltd This warranty contains the entire warranty Integrated Te...

Page 23: ...http www itvsystems com ua Integrated Technical Vision Ltd 23 ...

Page 24: ...ficators 8 access with ID 14 access with ID and PIN 14 proximity identificator 10 Interface RS 232 interface 17 RS 485 interface 16 J Jumpers 13 L LEDs 13 M Memory flash memory 7 nonerasable memory 8 Modes alarm mode 14 blocked mode 15 free pass mode 15 main mode 14 O Operation temperature 7 Outputs relay 7 terminals assignment 7 transistor 7 P Physical Dimensions 8 PIN 9 access with ID and PIN 14...