Alarms
6 720 802 419
(2012/06) en
65
17
Alarms
17.1 Alarms
This section includes:
•
Information log
(
Æ
Chapter 16.11 )
•
Delete information log
(
Æ
Chapter 16.11 )
•
Alarm log
(
Æ
Chapter 16.11 )
•
Delete alarm log
(
Æ
Chapter 16.11 )
•
Alarm history
(
Æ
Chapter 16.11 ).
17.2 Control unit and room sensor alarm lamp
The status lamp on the control unit is used to show ON/OFF status for the
heat pump but also to show possible alarms. The status lamp is therefore
also called alarm lamp.
The room sensor alarm lamp can be blocked.
The room sensor display is used to indicate alarms for some alarm
categories (
Æ
17.7 ). The display window slowly flashes red until the
alarm has been acknowledged in the heat pump control unit, or been
automatically reset.
The room sensor alarm display function is referred to as alarm lamp in
this chapter.
The room sensor alarm lamp can be blocked.
17.3 Alarm display
When an alarm/warning occurs, the display shows information about
what has happened. At the same time, information is saved in the alarm
log and alarm history.
17.4 Alarm buzzer at alarm
At an alarm the alarm buzzer on the heat pump sounds for one second
per alarm buzzer interval set. At certain times of the day the alarm buzzer
can be blocked or blocked altogether.
In the event of a warning alarm, the alarm buzzer does not sound.
17.5 Acknowledgement of alarms
Acknowledgement means that you have to press
to make the
alarm window disappear. What happens after acknowledgement is
described in the respective alarm description.
In most cases, warnings do not have to be acknowledged. The alarm
window disappears by itself once the warning cause has disappeared. It
is, however, possible to acknowledge the warning.
17.6 Alarm timer, alarm mode
In the event of an alarm that stops the compressor the control unit starts
a timer at 1h. If the fault does not recur additional heat may start when
the timer has counted down.
Behaviour
Function
The lamp lights green
continuously.
The heat pump is running.
The lamp flashes red
. There is an alarm which has not been
acknowledged.
The lamp lights red
continuously.
The alarm has been acknowledged but the
alarm cause remains.
The lamp flashes green
slowly.
The heat pump is in stand-by mode
1)
.
1) Stand-by means that the heat pump is running but no heating or hot water
demand exists.
Table 166 Alarm lamp control unit