Settings
6 720 802 419 (2012/06) en
64
16.11 Alarms
The different alarms that can occur are described in (
Æ
Chapter 17 ).
Under
Alarms
there is:
•
Information log
•
Delete information log
•
Alarm log
•
Delete alarm log
•
Alarm history
•
Alarm indication
> Information log
The information log shows information from the heat pump. The
information log symbol is displayed in the control panel start-up position
when there is active information.
> Delete information log
The information log is deleted here.
> Alarm log
The alarm log shows the alarms and warnings that have occurred. Alarm
category (
Æ
Chapter 17.7 ) is displayed in the top left corner of the
display and if the alarm is active, the alarm symbol is displayed both in
the alarm log and the initial menu of the control panel.
> Delete alarm log
The alarm log is deleted here
> Alarm history
Alarm history shows extensive information about the 20 most recent
alarms that have occurred. For example actual and set point values of the
temperature sensor and heat pump status at the time of the alarm.
Limited information is displayed for older alarms.
> Alarm indication
Settings for alarm buzzer and status lamp are made here.
>> Alarm buzzer signal
>>> Interval
B
Set the length of the alarm interval.
The alarm buzzer sounds for one second and is silent during the rest
of the interval. The setting applies to all alarm buzzers.
>>> Blocking time
B
Indicate the times between which the alarm buzzer may not give out a
sound.
All alarm buzzers are silent during a set interval.
>> Alarm indication control unit
>>> Block alarm buzzer
The setting applies only to the control unit's alarm buzzer.
>> Alarm indication room sensor
>>> Block alarm indicator lamp
B
Set if the indicator lamp should be off or not.
The setting applies to all room sensors.
>> General alarm level
>>> Alarms and warnings
No
means that alarms produce a signal on the general alarm output.
Yes
means that alarms as well as warnings produce a signal on the general
alarm output.
16.12 Access level
Access level is
Customer
as standard: This level gives you access to all
functions that the user requires. The installer also has access to the
additional functions required at installation.
16.13 Return to factory settings
B
Select
Return to factory settings
and
Yes
to reset all settings to the
factory settings. Settings made by the customer are not affected.
Factory setting
2s
Lowest value
2s
Highest value
3600s (60min)
Table 160 Interval
Factory setting
Off
Start time
0:00 - 23:45
Stop time
0:00 - 23:45
Table 161 Blocking time
Factory setting
No
Alternative
No/Yes
Table 162 Block alarm buzzer
Factory setting
No
Alternative
Yes/No
Table 163 Block indicator lamp
Factory setting
No
Alternative
No/Yes
Table 164 Alarms and warnings
Factory setting
No
Alternative
Yes/No
Table 165 Return to factory settings