ENGLISH
9
5.
START UP
5.1.
PREVIOUS CHECKUP
a) Is the machine leveled?
b) Voltage and frequency are the same as those on the nameplate?
c) Are the discharges connected and operating?
d) ** If air condensed: Is the air circulation and its temperature appropriate?
ROOM
WATER
MAXIMUM
43ºC / 109.4ºF
35ºC / 95ºF
MINIMUM
10ºC / 50º F
5ºC / 41ºF
** Is water pressure appropriate?
MINIMUM
0.1 MPa (14.5 psig / 1 bar)
MAXIMUM
0.6 MPa (87 psig / 6 bar)
f) The conductivity of the water must be at least 10 microSiemens
NOTE:
In case input water pressure is higher than 0,6 MPa (87 psig / 6 bar) install a pressure reducer. THE FAUCET CONNECTION
PRESSURE SHOULD NEVER BE REDUCED.
5.2. STARTING UP THE MACHINE
1. Connect to drinking water network. Open the water stopcock and check that there are no leaks.
2. Connect the machine to the electricity network. Turn the rear switch "ON".
3. The button on the control panel, PE1 (see Figure VI), must be lit red, when pressed, it will stay with a blue light flashing for 10
min.
4. After 10 minutes of the timer, the machine will start up and PE1 will remain with a steady blue light.
5. Check that there is no element that rubs or vibrates.
6. Check that it produces ice correctly. *It is normal that in the first instants a little water will drop instead of ice*.
7. Check that there is no alarm glowing on the control panel. In such case, restart the machine. If the problem persists, call the
technical service.