You are now the owner of a Goulds pump. This pump 
was carefully inspected and subjected to fi nal tests before 
releasing for shipment. In order to assure maximum 
performance, please follow the simple instructions in this 
manual.

RECOMMENDED PRECAUTIONS

  

1.

 Avoid system pressures that may exceed the maxi-

mum working pressure of the pump.

  

2.

 Should the fl uid temperature rise more than 50ºF. 

above ambient, expansion joints must be installed on 
both the suction and discharge ports to relieve any 
stress on the pump casing.

  

3.

 All electrical wiring of the pump installation must be  

done by a licensed electrician who will observe all 
national and local electrical codes. All motors require 
a magnetic starter with current overload protection.

  

4.

 No modifi cations, additions or deletions should be 

made to the pump, without prior approval of the 
factory.

  

5.

 In systems where shock wave pressures may be gener-

ated, protective devices such as check valves/gate 
valves, etc., must be installed on the discharge line 
to prevent shock pressures from entering the pump 
casing.

  

6.

 In systems containing discharge check valves, gate 

valves, etc., the pump will not prime against a closed 
valve. Check the discharge valves making sure they 
are open before attempting to prime the pump. If 
there is a possibility of air being entrapped in the 
pump casing, install an automatic venting device to 
bleed off the air.

  

7.

 This pump is designed primarily for water use. Before  

pumping other liquids, read carefully the 

CAUTION 

 

below.

  

8.

 Overheated pumps are dangerous. Burns or explosion 

could occur due to steam pressure. Operating pumps 
with suction and discharge closed is one cause of 
severe overheating. If overheating of the pump occurs: 
1. Stop pump immediately, 2. Allow pump to cool, 3. 
Slowly and cautiously vent pump.

  

9.

 Drain casing completely when servicing pumps han-

dling volatile or harmful liquids.

10.

 Do not use in a combustible atmosphere.

11.

 Make daily checks of the tightness of suction and 

discharge pipe, drain, fi lter plug and pump gaskets. 
Operation should not proceed until all of the above 
items have been checked and are tight.

12.

 After servicing the pump, always install the coupling  

guards, belt guards and other safety devices as origi-
nally found prior to disassembly.

The performance of Goulds pumps are 
based upon clear, cold, fresh water with 

suction conditions as shown on the performance curve. 
If used to pump other liquids, pump performance may 
differ from rated performance based on the different 
specifi c gravity, temperature, viscosity, etc. of the liquid 
being pumped. A standard pump may not be safe for 
pumping all types of liquids, such as toxic, volatile or 
chemical liquids, or liquids under extreme temperatures 
or pressures. Please consult your Goulds Pumps catalog 

as well as local codes and general references to determine 
the appropriate pumps for your particular application. 
Since it is impossible for us to anticipate every applica-
tion of a Goulds pump, if you plan to use the pump for a 
non-water application, consult Goulds Pumps beforehand 
to determine whether such application may be proper 
or safe under the circumstances. Failure to do so could 
result in property damage or personal injury.

OPERATING INSTRUCTIONS

GENERAL

• Our shipping container has been specifi cally designed 

to prevent transit damage. However, any indications 
of damage or shortage should be carefully noted on 
the delivery ticket and a claim fi led promptly with the 
carrier.

PROPER LOCATION

• By placing your Goulds pump on a fi rm, level founda-

tion or between fi rmly supported pipelines, you reduce 
harmful vibrations and unnecessary noises.

• While EV series pumps are self-priming and may be 

located above the source of liquid supply, best pump 
operation is obtained by locating the pump as close as 
possible to the liquid being handled, keeping in mind a 
pump can push liquid more effectively than it can pull 
or draw liquid. Provide the necessary space around the 
pump for future inspection and servicing of the unit.

PIPING

• All piping should be independently supported to elimi-

nate excessive strain on the pump. Avoid unnecessary 
friction losses. Keep your piping as short as possible 
and use the fewest possible elbows and fi ttings. Pipe 
joint compound that will not dissolve in the liquid 
being pumped should be used on all joints. Gate valves 
combined with unions or fl anges, on both sides of the 
pump, will facilitate pump removal without disturbing 
the piping. It is occasionally advantageous to use suc-
tion pipe one size larger than that for which the pipe 
is fi tted. Eccentric reducers should be used to change 
pipe sizes.

STRAINER ADVISABLE

• Protect your investment. Install a strainer on the suc-

tion line. This will eliminate clogging of the pump, 
poor performance and excessive wear. A 16 mesh 
strainer submerged one foot below the liquid level is 
adequate for EV series pumps. In-line strainers are 
available from your Goulds Pumps dealer. Piping that 
has a continuous rise will facilitate draining the system.

VALVES

• Install a check valve on the discharge side of the pump. 

This will prevent high surge back pressures from 
damaging the pump. If the pump is disconnected this 
check valve will prevent the liquid from draining the 
discharge line.

• Some installations may require the throttling of the 

pump. Gate valves may be used on the discharge side. 
Place the check valve between pump and gate valve.

CAUTION

Summary of Contents for Goulds Pumps Marlow 20EVP Series

Page 1: ...n Manual for Reference ITT Goulds Pumps Marlow Series 20EVP Installation Operation and Maintenance Instructions Commercial Water Goulds Pumps is a brand of ITT Corporation www goulds com Engineered for life ...

Page 2: ...tenance 4 Warning 4 Caution 4 Instructions for Licensed Electricians 4 Troubleshooting Guide 5 Repair Parts 6 Limited Warranty 8 Please fill in data from your pump nameplate Warranty information is on page 8 Pump Model Serial Number Dealer Dealer s Phone Number Date of Purchase Installation Date Owner s Information Owner s Information ...

Page 3: ...safe for pumping all types of liquids such as toxic volatile or chemical liquids or liquids under extreme temperatures or pressures Please consult your Goulds Pumps catalog as well as local codes and general references to determine the appropriate pumps for your particular application Since it is impossible for us to anticipate every applica tion of a Goulds pump if you plan to use the pump for a ...

Page 4: ... been in cor porated into our self lubricating shaft seal The liquid being pumped cools and lubricates the seal therefore the pump should never be run dry A seal well vent has been provided to protect the electric motor from liquid damage should the seal leak DO NOT plug this vent If leakage becomes excessive replace the seal assembly MAINTENANCE If your pump is not used for a few days drain the l...

Page 5: ...akage Worn seal Replace seal From Seal Well Vent Will Not Worn seal Replace seal Hold Prime Suction lift too high Relocate pump closer to supply Air leak in suction line Fix leak Performance Poor Worn impeller or seal Replace with new impeller or seal Suction lift too high Relocate pump closer to supply Low Flow Motor not up to speed low voltage Larger lead wires Or Pressure Air leak Tighten all j...

Page 6: ...rvice IMPORTANT How to use the drawing to order parts The above grouping of parts illustrations cover many different Goulds Pumps models including your own pump The table on the left page indicates the name of each part Should you need a replacement refer to the draw ing locate the part that matches your pump part Contact your local Goulds Pumps dealer and supply him with the key number and descri...

Page 7: ...7 NOTES ...

Page 8: ...uipment d Consequential damages of any kind and e Reimbursement for loss caused by interruption of service For purposes of this warranty the following terms have these definitions 1 Distributor means any individual partnership corporation association or other legal relationship that stands between Goulds Pumps and the dealer in purchases consignments or contracts for sale of the subject pumps 2 Dea...

Page 9: ...ste manual para consultas ITT Goulds Pumps Serie Marlow 20EVP Instrucciones de Instalación Operación y Mantenimiento Agua Comercial Goulds Pumps es una marca de ITT Corporation www goulds com Engineered for life ...

Page 10: ...trucciones para electricistas con licencia 12 Guía de solución de fallas 13 Refacciones 14 Garantía limitada 16 Favor de copiar a continuación los datos de la placa de datos de su bomba La información de la garantía está en la página 16 Número de modelo de la bomba Número de serie Distribuidor Teléfono del dist Fecha de compra Fecha de instalación Información del propietario Información del propie...

Page 11: ...s de succión que se muestran en la curva de desempeño Si usa la bomba para otros líqui dos el desempeño de la misma puede diferir del nominal en base a la diferencia de gravedad temperatura viscosidad etc Puede ser que una bomba estándar no sea segura para bombear todos los tipos de líquidos como tóxicos volátiles o químicos o líquidos bajo temperaturas o presiones extremas Por favor consulte el c...

Page 12: ...hielo que se puede formar rompa el tanque o partes internas Para mantener un desempeño excelente de la bomba siga las instrucciones de almacenamiento del fabricante del motor LUBRICACIÓN Nuestro sello de eje autolubricante lleva los últimos avances de la ingeniería El líquido que se va a bombear enfría y lu brica el sello por lo tanto la bomba nunca deberá operarse en seco Se ha proporcionado un s...

Page 13: ...el pozo No mantiene la Sello gastado Reemplace el sello bomba cebada Elevación de succión muy alta Reubique la bomba más cerca del suministro Fuga de aire en la línea de succión Escape del arreglo Pobre desempeño Sello o impulsor gastado Reemplace el sello o impulsor por uno nuevo Elevación de succión muy alta Reubique la bomba más cerca del suministro Flujo o presión bajos El motor no alcanza la ...

Page 14: ...rvicio IMPORTANTE Cómo usar el dibujo para solicitar partes de repuesto Las ilustraciones anteriores de grupos de partes cubren diferentes modelos de Goulds Pumps incluyendo la bom ba de usted La tabla en la página izquierda indica el nombre de cada parte Si necesitara cambiar una de ellas consulte el dibujo y localice la parte que coincida con la parte de su bomba Contacte a su distribuidor local...

Page 15: ...15 NOTAS NOTAS ...

Page 16: ...stalación del equipo reemplazado d daños emergentes de cualquier naturaleza y e el reembolso de cualquier pérdida causada por la interrupción del servicio A los fines de esta garantía los términos Distribuidor Comerciante y Cliente se definen como sigue 1 Distribuidor es aquel individuo sociedad corporación asociación u otra entidad jurídica que opera entre Goulds Pumps y el comerciante para la comp...

Page 17: ...nsultatif ITT Goulds Pumps Marlow série 20EVP Directives d installation d utilisation et d entretien Systèmes d alimentation en eau commerciaux Goulds Pumps est une marque d ITT Corporation www goulds com Engineered for life ...

Page 18: ...ens 20 Diagnostic des anomalies 21 Liste de pièces de rechange 22 Garantie limitée 24 Inscrire ci dessous les informations pertinentes indiquées sur la plaque signalétique de la pompe La garantie se trouve en page 24 No de modèle de la pompe No de série de la pompe Détaillant No de tél du détaillant Date d achat Date d installation Informations pour le propriétaire Informations pour le propriétair...

Page 19: ...us une très forte pression Il vaut mieux consulter le catalogue Goulds Pumps ainsi que les codes locaux et les ouvrages de référence généraux pour sé PRÉCAUTIONS RECOMMANDÉES ATTENTION lectionner la pompe convenant à un usage particulier Goulds Pumps ne peut prévoir tous les usages faits de ses pompes Il est donc recommandé de s adresser à Goulds Pumps si l on prévoit utiliser une pompe pour un li...

Page 20: ...nné que le liquide pompé refroidit et lubrifie la garniture la pompe ne doit jamais fonctionner à sec L orifice de fuite du logement de garniture protégera le moteur électrique du liquide s il y a fuite de la garniture NE PAS boucher l orifice Si la garniture fuit trop la remplacer ENTRETIEN Si la pompe n est pas employée pendant quelques jours la vidanger pour prévenir la formation de rouille aggrav...

Page 21: ...ture mécanique usée Remplacer la garniture désamorce Hauteur d aspiration excessive Rapprocher la pompe de sa source de liquide Air entrant dans la tuyauterie d aspiration Colmater la fuite Le rendement est Roue ou garniture mécanique usée Poser une roue ou une garniture neuve faible Hauteur d aspiration excessive Rapprocher la pompe de sa source de liquide Le débit ou la pression Moteur trop lent...

Page 22: ...mmandées Service critique pièces de rechange pour l exportation et stocks du distributeur recommandés IMPORTANT Mode de commande des pièces La liste de pièces et le dessin figurant dans la présente page s appliquent à divers modèles de pompes Goulds y compris la 20EVP Au besoin se servir de la liste et du dessin pour trouver le numéro et le nom d une pièce à rem placer puis les indiquer au détailla...

Page 23: ...23 NOTES ...

Page 24: ... soit e ni les pertes découlant de la panne Aux fins de la garantie les termes ci dessous sont définis comme suit 1 Distributeur signifie une personne une société de personnes une société de capitaux une association ou autre entité juridique servant d intermédiaire entre Goulds Pumps et le détaillant pour les achats les consignations ou les contrats de vente des pompes en question 2 Détaillant veut d...

Reviews: