5.
Push the flinger (507) onto the shaft (210) till it rests axially against the shoulder of the shaft. Be-
tween flinger (507) and Bearing bracket lantern (344) there must remain a clearance of at least 0.7
mm | 0.03 in.
If necessary you can use a driver for mounting.
Item No.
Description
1.
Driver
Figure 22: Use of driver foe mounting
6.
For mounting of the shaft sealing (packing or mechanical sealing) see separate description "Mount-
ing Instruction of Shaft Sealing" and Removal of Shaft Sealing.
7.
For impellers with back vanes the axial clearance between the back vanes and the casing cover
(161) should be checked after mounting the impeller (230) and tightening the impeller nut (922) (see
Clearance at impellerchapter.
8.
After the mounting of the back pull out assembly, and its assembly into the volute casing, turn the
shaft and control the free moving of the pump in this way. The shaft sealing will cause slightly resist-
ance when turning, but there must not be any contact between metal parts.
9.
Before starting the pump check alignment of the coupling. This can be dropped on pumps with
spacer coupling, if pump casing and motor were not disassembled.
NOTICE:
Before starting the pump do not forget to fill in oil.
NOTICE:
Before starting the pump do not forget to install and connect all security devices.
6.15 Reassembly
Model ICP, ICPI, ICPH, ICPIH Installation, Operation and Maintenance Instruction
41