Item No.
Description
1.
Screw part 1 to the bearing cover
2.
Screw part 1 and part 2 together, which fixes the adjusting piece
Figure 11: Coupling guard assembly - Step 3
4.3 Drive
On selecting the motor size care has to be taken, that the requirements according to ISO 5199 are fulfil-
led.
Note the Operating Instructions of the motor manufacturer.
On application in zone 1 and 2 a motor with valid Atex-certification must be used.
If in the process of the repair a new motor is used , the following has to be noticed:
•
The motor must comply with the requirements stated in sheet 1220.1A608 (order from manufactur-
er, on demand).
•
Clean motor end and motor flange of new motor carefully (remove varnish).
4.4 Final Control
Check alignment of coupling according to
● Alignment of coupling on page 20
to turn the unit easily by hand at the coupling.
4.3 Drive
24
Model ICP, ICPI, ICPH, ICPIH Installation, Operation and Maintenance Instruction