Figure 26:
5.
Add to this measurement the impeller clearance required from
Table 4: Impeller Clearances on
.
Select four (4) sets of shim(s) (329B) equal to this thickness.
NOTICE:
In some cases, finding an exact match may not be possible. In this case, select the next clos-
est size greater.
6.
Loosen the motor locking bolts (370B). Using the jacking bolts (370D) back the motor (338) away
from the pump until enough space is available to insert the shim(s) (329B).
7.
Insert the shim(s) (329B) around the motor locking bolts (Fig. 27).
Figure 27:
8.
Loosen the jacking bolts (370D).
9.
Tighten the motor (338) locking bolts securely.
10. Check shaft for free turning.
5.9 Feeler gauge method (all but CV)
3196CC Installation, Operation and Maintenance Instructions
35