CANNON STANDARD
page 12 of 20
ASSEMBLY AND WIRING INSTRUCTION
CA-BAYONET IP69K
Circular Connector with Protection Class IP69K
CAS25092E
Bearbeitet:
Geprüft:
Norm:
Änd.-Stand:
Änd.-Datum:
AKU/FA
AKU/FA
G5820W
JPE 18.12.2018
ITT Cannon GmbH, D-71384 Weinstadt
5
Place wired contact into insertion tool in a way that
contact, wire and insertion tool are axial to each other. Use
the correct insertion tool (see 3.3).
Insert contacts by applying slow, continuous pressure, until
it snaps into its position.
Do not install damaged or bent contacts! If a contact is
damaged during the insertion this contact has to be
removed. A new contact has to be installed.
6
After insertion operation remove the insertion tool
cautiously.
Avoid any movement of the tool during the insertion
process which is not axial to the contact / insulator.
7
After insertion of contacts remove the guide pins if
necessary (socket contacts 15S/16S/15/16/12and 25 only).
After insertion of the contacts, check connector on the
mating side to ensure that all contacts are on the same
level.
8
Connector with fully assembled contacts.