background image

OPERATING INSTRUCTIONS / MAIN SEAL REPLACEMENT 
Page 1 of 3 

 

 

www.fastestinc.com 

Roseville, MN 
Toll Free at 1-800-444-2373 
Fax 651-645-7390 

 

 

WP144 Rev B       6/25/2021 

60 Series for 
Male Threads 

70 Series for Tube 
Configurations 

COLLETS 

SLEEVE BACK 
COLLETS OPEN 

BODY 

TERMINATION 

PORT 

60V & 70V Series Valve Connectors 

DESCRIPTION: Sleeve Activated Connectors for Sealing Male 
Threads and Formed Tube Ends. 

 

 
 
 
 
 
 
 
 

 

 

 
 

 

CAUTION: 60V & 70V Connectors are internally valved. Disconnecting 
while pressurized can cause rapid separation. Termination pressure 
should be relieved prior to disconnecting connector. 
Connecting while pressurized is doable but not recommended. 
Example of connection forces; At 80psi with a Body Size 3 connector 
the force to connect is approximately 44 lbs. 
Body Size 4 connector is approximately 56 lbs. at 80psi. 

 
Please thoroughly read the instructions prior to operating the connector. This 
connector is designed to provide a safe, reliable leak-tight seal and 
connection when properly maintained and operated.   

  The connector is designed to mate with a specific application.  Verify the 

application prior to the introduction of pressure or processing. Use only in 
a safe environment. Safety chains and guards are recommended for all 
applications. 

  Connectors are NOT designed for permanent connections and are for 

temporary connections only. 
 

DO NOT EXCEED pressure rating as marked on connector or 
corresponding literature. Before using, verify that this pressure rating is 
within your working pressures. 

 

Installation 

 

Operation 

 

Main Seal Replacement 

 

Connector Maintenance 

 

Safety Warnings - Guidelines 

 
INSTALLATION: 

1.  Connect media hose/fitting to the termination port on connector. 

a.  Pipe tape and or thread sealant is recommended. 

 
 
 
 
 
 
 
 

OPERATION: 

1.  Slide sleeve back and collets will open. 

 
 
 
 
 
 
 
 
 
 
 
  

2.  Insert male end of the component to be tested into collets and press 

against connector. Spring action forces knurled sleeve forward, collaps-
ing collets to the gripping and sealing position. 

3. 

Note to Operator; The Type 60/70 Connector will 
connect better when you do the following. Hold exposed 
area of Body at termination end of connector. Try to 
keep hands free from the sleeve as you connect to your 
test piece. 