CANNON STANDARD
page 19 of 20
ASSEMBLY AND WIRING INSTRUCTION
CA-BAYONET IP69K
Circular Connector with Protection Class IP69K
CAS25092E
Bearbeitet:
Geprüft:
Norm:
Änd.-Stand:
Änd.-Datum:
AKU/FA
AKU/FA
G5820W
JPE 18.12.2018
ITT Cannon GmbH, D-71384 Weinstadt
Wire Stripping Length for System Cable
Table 1
Shell
Size
Length C
[mm]
Length B
[mm]
Length A
[mm]
10SL
32 ±1
ca. 32
see table2
14S
34 ±1
ca. 34
see table2
16S
34 ±1
ca. 34
see table2
18
35 ±1
ca. 35
see table2
20
35 ±1
ca. 35
see table2
22
43 ±1
ca. 43
see table2
24
43 ±1
ca. 43
see table2
28
44 ±1
ca. 44
see table2
Table 2
Contact
size
Insulation diameter
in mm
Wire stripping length
in mm
10 / 20
max. 3,0
6,0 +0,5
15 / 16
max. 3,3
6,0 +0,5
25 / 12
max. 4,3
6,0 +0,5
60 / 100 / 8
max. 6,5
11,0 +0,8 -0,4
160 / 4
max. 9,4
11,0 +0,8 -0,4
500 / 0
max. 14,0
13,0 +0,8 -0,4
Clamping Torque for Endbell, Housing and Coupling Nut
Table 3
Shell
ENDBELL HOUSING
Size
Clamping Torque
10SL
2,5
– 3 Nm
14S
4
– 5 Nm
16S
6
– 7 Nm
18
6,5
– 8 Nm
20
7
– 9 Nm
22
8
– 10 Nm
24
11
– 13 Nm
28
13
– 16 Nm
Table 4
COUPLING NUT
Cable Sealing Area
Wrench Size
Clamping Torque
D07
16 mm
1,0 Nm ±0,2
D09
19 mm
1,3 Nm ±0,2
D11
22 mm
1,7 Nm ±0,2
D13
25 mm
2,3 Nm ±0,2
D14
27 mm
3,0 Nm ±0,2
D17
32 mm
3,0 Nm ±0,2
D19
34 mm
3,5 Nm ±0,2
D20
36 mm
3,5 Nm ±0,2