![ITS Telecom 1700264 Operation Manual Download Page 29](http://html1.mh-extra.com/html/its-telecom/1700264/1700264_operation-manual_2096138029.webp)
MITS Janus Time Engine
Page 29 of 39
Copyright© Instrumentation Technology Systems 2020
20200929
Group
Command
String
Variable values
Notes
PTP
PTP/NTP
Network
Time Source
^YTSxn
x= P,N,S
when x=P (PTP master/slave)
n= 0,1
0=Master
1=Slave
when x=N (NTP master/slave)
n= 0,1
0=Master
1=Slave
when x=S (NTP/PTP as source)
n= 2,3
2=NTP as source
3=PTP as source
^YTS?
Queries the current value
Return =(19h)TS(32h) value<CR> as
ASCII
Value= (19h)TSNTP:Slave,
(19h)TS(32h)PTP:Master or
(19h)TS(32h)PTP:Slave
PTP
PTP Master
Settings
^YPTxnn
x=timer type where
A=Announce timer (+0 to +6)
S=Sync Timer (-5 to +3)
nn=value (log =2^nn) where nn
All negative values are for x=S only
6 = 64 sec; x=A only
-5 = 1/32 5 = 32 sec; x= A only
-4 = 1/16 4 = 16 sec; x= Aonly
-3 = 1/8 3 = 8 sec
-2 = 1/4 2 = 4 sec
-1 = 1/2 1 = 2 sec
0 = 1 sec
Up to 10 subscribers may
be registered to the JTE.
Up to 10 boundary clocks
and/or PTP terminal
devices may be
synchronized by the JTE.
^YPT?
Queries the current value
Return =(19h)PT(32h)A:nn, S:nn<CR>
Time
Ref
PRIORITY A
source
^YPAx
x=1,2,3,4, where
1 = IRIG
2 = GPS (if present)
3 = PTP/NTP (factory default)
4 = 1PPS
Priority A is always the
DESIRED MASTER, if
available.
NTP w1ll not be available
without a server address.
GPS will not be available
without the option
installed.
Priority selections must
always be in sequential
^YPA?
Query current value
Return =(19h)PA(32h)value<CR> as
ASCII
Value=NONE, IRIG, GPS, PTP/NTP or
1PPS