![ITS Telecom 1700264 Operation Manual Download Page 25](http://html1.mh-extra.com/html/its-telecom/1700264/1700264_operation-manual_2096138025.webp)
MITS Janus Time Engine
Page 25 of 39
Copyright© Instrumentation Technology Systems 2020
20200929
Group
Command
String
Variable values
Notes
^YCA?
Queries current value
Return =(19h)CA(32h)valueHZ<CR>
as ASCII
Value=
1Hz,10Hz,100Hz,1kHz,10kHz,100kHz,
1MHz or 10MHz
Example: (19h)CA 10Hz<CR>
Clocks Clock B Out
^YCBxxxx<CR>
Where xxxx=0001 (default) to 1000
The value of xxxx produces an output
of 1 to 1000 Hz, respectively.
^YCB?
Queries current value
Return=(19h)CB(32h)value<CR>
Value = 1Hz-1000Hz
Example: (19h)CB 101Hz<CR>
Clocks Invert Clock A
out
^YCIx
x=0 is in phase with 1 sec tick
=1 is inverted phase
^YCI?
Queries current value
Return=(19h)CI(32h)value<CR> as
ASCII
Value=1 or 0
Clocks Invert Clock B
out
YCNx
x=0 is in phase with 1 sec tick
=1 is inverted phase
YCN?
Return=(19h)CN(32h)value<CR> as
ASCII
Value=1 or 0
GPS
GPS
DYNAMIC
MODE
^YDMn
n= 1 to 5 where
1 = Stationary (Factory Default)
2 = Man Pack
3 = Land Vehicle
4 = Marine
5 = Airborne
Only if the GPS option has
been purchased.
^YDM?
Queries current value
Return =(19h)DM(32h)value<CR>
where value=1-5,0 (none)