ITRON OpenWay OWR-1000-001 Installation Manual Download Page 10

Chapter 1  Introduction 
 

 

DRAFT  OpenWay Installation Guide 

 

Summary of Contents for OpenWay OWR-1000-001

Page 1: ...OpenWay 2 4ZR IPP Range Extender Installation Guide DRAFT OpenWay...

Page 2: ...erence This device must accept any interference that may cause undesirable operation This device must be permanently mounted such that it retains a distance of 20 centimeters 7 9 inches from all perso...

Page 3: ...on Flowchart 5 Configure the 2 4ZR IPP Range Extender 6 Reconfigure an Installed 2 4ZR IPP Range Extender 7 Read an Installed 2 4ZR IPP Range Extender 8 Select a Mounting Location 8 Link to a CENTRON...

Page 4: ...Contents iv DRAFT OpenWay Installation Guide...

Page 5: ...or laptop computer loaded with Endpoint Link or Endpoint Link Pro software version 5 4 or higher OpenWay Belt Clip Radio AMI 0100 001 2 4GZ OpenWay Gas Module Installation Guide TDC 0816 xxx Equipment...

Page 6: ...Before You Begin vi DRAFT OpenWay Installation Guide...

Page 7: ...onents or there may be too great a distance between the meter and the gas module The range extender is strategically placed between the meter and the gas module providing an extension to the gas modul...

Page 8: ...tional specifications Description Power source Two A cell lithium batteries Tamper detection None FCC compliance Part 15 certified Intrinsic safety UL Class I Division 1 Groups C and D Product identif...

Page 9: ...e Model OWG 5001 xxx or later with IPP Related Documents 2 4GZ OpenWay Gas Module Installation Guide Direct Mount TDC 0816 xxx Endpoint Link Pro Server Software User s Guide TDC 0737 xxx Endpoint Link...

Page 10: ...Chapter 1 Introduction 4 DRAFT OpenWay Installation Guide...

Page 11: ...list in the order listed Installation Checklist Step Procedure 1 Configure the 2 4ZR IPP Range Extender on page 6 2 Select a Mounting Location on page 8 3 Link to a CENTRON Meter on page 8 4 Link to t...

Page 12: ...ons parameters with a Bluetooth enabled FC200 handheld computer or a laptop computer loaded with Endpoint Link or Endpoint Link Pro software the OpenWay Belt Clip Radio and the same configuration file...

Page 13: ...d computer running Endpoint Link software 3 Using Endpoint Link verify successful configuration of the range extender Note If the 2 4GZ OpenWay Gas Module is not yet programmed then it should be progr...

Page 14: ...faces until the final location is verified If the range extender can be mounted within sight of the meter and the gas module the location is probably adequate Select a location for the range extender...

Page 15: ...e the radio joining process hold the Itron magnet on the side of the range extender over the label for approximately five seconds and then remove the magnet The range extender searches for CENTRON met...

Page 16: ...procedure in the order listed in the Installation Checklist on page 5 The radio link from the range extender to the CENTRON meter must be established before you establish a link to the gas module You...

Page 17: ...rds repeat the procedure Link to a CENTRON Meter on page 8 None 0 2 After establishing a connection between the gas module and the range extender return to the range extender and verify the signal qua...

Page 18: ...tender in the optimum location determined by the procedures Link to a CENTRON Meter on page 8 and Link to the Gas Module on page 10 3 Using two screws mount the device to a stationary object Caution D...

Page 19: ...he steps in Configure the 2 4ZR IPP Range Extender on page 6 Repeat the steps in Link to a CENTRON Meter on page 8 Important The order in which you perform the magnet swipes when setting up RF paths i...

Page 20: ...Chapter 3 Troubleshooting 14 DRAFT OpenWay Installation Guide...

Page 21: ...entification 2 installation 5 installation flowchart 5 installation overview 5 intrinsic safety 2 L location 8 M magnet v materials 2 meter compatibility 2 modulation 2 mounting 12 O operating humidit...

Page 22: ...Index 16 DRAFT OpenWay Installation Guide...

Reviews: