Auto disconnect configuration
The Intelis gas meter can be configured for an automatic shut off for the following event
types.
• High flow. Configuration for a high flow event enables an automatic shut off if the high
flow threshold is reached or exceeded.
• High temperature. Configuration for a high temperature enables an automatic shut off if
the high temperature threshold is reached or exceeded.
Intelis meter specifications
This section lists the OpenWay Riva Intelis Gas meter product specifications.
Specification
Specification value
Meter capacity
250 cubic feet per hour
Measurement principle
Ultrasonic time of flight
Gas type
Natural gas Type E, H, L
Hub center-to-center
6 inches
Hub size options
• 10LT
• 20LT
• 30LT
• 1A/Standard
• 1-1/4"
• ISO G 1-1/4"
Meter MAOP
5 PSIG
Meter type
Temperature compensated (TC) or non-temperature
compensated (NTC)
Intrinsically safe
UL Class I, Div 1
LCD displayed units
CCF (100 x cubic foot) or cubic meter
LCD resolution
00000.001 CCF (0.1 CF) or 00000.001 m
3
Accuracy
Class 1 and ±0.5% at room temperature
Case
Aluminum case with ASA 49 gray powder coat finish
Valve
Gate valve, maximum 0.035 CFH leakage rate (14% of
pilot flow)
Pulse width
10 ms - 1000 ms (1 second)
Pulse weight (volume per pulse)
0.10 CF, 0.25 CF, 0.50 CF, 1.0 CF, 10 dm
3
, 50 dm
3
Operating temperature ratings
Measurement -30° F (-34° C) to +131° F (55° C)
Valve -13° F (-25° C) to +131° F (55° C)
500G -40° F (-40° C) to +158° F (70° C)
Storage temperature ratings
Measurement -40° F (-40° C) to +131° F (55° C)
Valve -40° F (-40° C) to +131° F (55° C)
500G -40° F (-40° C) to +158° F (70° C)
The OpenWay® Riva Intelis Gas Meter
OpenWay® Riva Intelis Gas Installation Guide TDC-1782-000
9
Proprietary and Confidential