![ITRON OpenWay Intelis Installation Manual Download Page 10](http://html1.mh-extra.com/html/itron/openway-intelis/openway-intelis_installation-manual_2096053010.webp)
OpenWay Riva Intelis Gas Meter LCD
The Intelis meter LCD provides a visual display through a liquid crystal display (LCD). The
LCD:
• Displays a 5-digit plus three (in CCF) in NTC or TC measurement.
◦ NTC meters display Vm.
◦ TC meters display Vb.
• Displays different menu pages in a pre-defined sequence.
◦ The time each menu page is active is configurable.
◦ When the last menu page is reached, the process loops to the first menu page until the
configured timeout is reached.
Note
: Two additional menu pages provide overflow condition information and an
interface to perform an LCD test. The LCD test is initiated by a long press. These
additional menu pages are not a part of the normal sequence.
• Displays current alarms.
Note
: X (1) indicates the number of currently active alarms. Before the display moves to
the next menu page, all active alarms are displayed. If there are no alarms,
NO ALARM
displays.
Available alarms include:
◦ Backflow
◦ Overflow
◦ Magnetic tamper
◦ Temperature
◦ Valve
◦ 123 (alarm code)
• Displays current volume consumption measured under an alarm condition.
The OpenWay® Riva Intelis Gas Meter
OpenWay® Riva Intelis Gas Installation Guide TDC-1782-000
7
Proprietary and Confidential