Operation: C1S Version
26
CENTRON® Meter Technical Reference Guide
Segment Check
The Segment Check Register addresses applications requiring display scrolling between
kWh and a full segment check. See Display Timing
for factory programming options.
Figure 24: Segment Check
Although the DEL and REC indicators are ON during segment check, they are not
currently used.
Factory Programming Options
Display Timing
The display will scroll between the billing register and the segment check mode based on
the factory programming option.
Option
Description
1
7 second billing register display, 1 second blank, 7 second segment
check display (7/7)
2
7 second billing register display, 1 second blank, 1 second segment
check display (7/1)
3
Only the billing register is displayed (7/0)
Digits and Multipliers
The following digit and multiplier settings are available for factory programming:
4 digits x 1 kWh
4 digits x 10 kWh
5 digits x 1 kWh
Factory programmable multipliers are available for CL20 (x20, x40, and x80) applications.
This allows the meter to display and transmit via RF primary readings. Meters are labeled
accordingly when factory programmed.
Summary of Contents for Centron
Page 1: ...CENTRON Meter Technical Reference Guide Effective Date October 2006...
Page 10: ...Table of Figures x CENTRON Meter Technical Reference Guide Notes...
Page 20: ...General Information 10 CENTRON Meter Technical Reference Guide Notes...
Page 50: ...Operation C1SC Version 40 CENTRON Meter Technical Reference Guide Notes...
Page 96: ...Glossary of Terms 86 CENTRON Meter Technical Reference Guide Notes...
Page 100: ...Index 90 CENTRON Meter Technical Reference Guide Notes...