![ITRON Centron Technical Reference Manual Download Page 26](http://html1.mh-extra.com/html/itron/centron/centron_technical-reference-manual_2096034026.webp)
Installation
16
CENTRON® Meter Technical Reference Guide
Figure 11: Board-to-Board Connector, Bottom
8
Ensure the board-to-board connector is fully seated by pressing firmly in on the middle
of the connector.
Figure 12: Board-to-Board Connector, Top
9
Carefully replace the inner protective cover. Engage the top snaps first, taking care to
place the slot at the top of the cover over the IR light pipe. Failure to do so could break
the light pipe. Ensure that all four meter base tabs are engaged with the slots at the top
and bottom of the inner cover.
10
Place the cover over the meter base until the flange on the cover is flush with the flange
on the meter base.
11
Turn the cover clockwise until the locking tabs are fully engaged with the meter base.
12
If the cover has a Demand Reset or an Optical Connector, be sure these are properly
aligned with their corresponding accessory on the register faceplate. If not aligned
correctly, the Demand Reset or Optical Connector will not function properly. If the
Demand Reset plunger is not in the retracted position before turning the outer cover, the
mechanism may be damaged.
Summary of Contents for Centron
Page 1: ...CENTRON Meter Technical Reference Guide Effective Date October 2006...
Page 10: ...Table of Figures x CENTRON Meter Technical Reference Guide Notes...
Page 20: ...General Information 10 CENTRON Meter Technical Reference Guide Notes...
Page 50: ...Operation C1SC Version 40 CENTRON Meter Technical Reference Guide Notes...
Page 96: ...Glossary of Terms 86 CENTRON Meter Technical Reference Guide Notes...
Page 100: ...Index 90 CENTRON Meter Technical Reference Guide Notes...