Input/Output Settings SW1 (continued)
DIP switch 1-4 – Release modes [Default OFF]
•
ZP2 (OFF) – In singulated release mode (assuming accumulated conveyor) each zone will advance when its
downstream zone is unoccupied
•
ZP1 (ON) – In train/slug release mode (assuming accumulated conveyor) all zones will advance in unison
DIP switches 1-5 and 1-6 - Motor Direction
DIP
Switch
Function
ON
OFF
Default
Setting
1-5
Motor A direction*
FE
FS/FP
FE
FS/FP
ON
CCW
CW
CW
CCW
1-6
Motor B direction*
FE
FS/FP
FE
FS/FP
ON
CCW
CW
CW
CCW
* Motor direction (as viewed from the cable side; PM486 series) is independent of ZPA logic flow direction.
DIP switch 1-7 – Zone Count
•
1 Zone on a card (ZONE 1; ON)
o
Connect motor to CN101 Motor A and sensor to CN301 sensor A
When using one motor per zone set SW2-4 to OFF
When using two motors per zone set SW2-4 to ON
•
2 Zones on one card (ZONE 2; OFF) [Default]
o
Utilizes both motor ports and sensor ports for two individual zones
DIP switch 1-8 – Error output function
•
Pulsed output (PLS; ON)
o
Used when connecting the error output to an IB-E03 / 04 remote input 1 (CN301-1 on IB-E series)
•
Output signal (ERR ON; OFF) [Default]
o
Outputs a signal when an error occurs
PNP signal with SW2-3 ON
NPN signal with SW2-3 OFF