Features 

 

 

Adjustable acceleration and 
deceleration time (0 to 2.5s) 

 

Stable speed operation 

 

Manual or automatic recovery of the 
thermal overload device 

 

One (1) rotary switch to select up to 10 
different fixed speeds or external 
voltage input for up to 20 fixed speeds 

 

Forcibly stops the motor if motor lock 
last for 4 seconds or thermal overload 
error lasts for 1 second or more. 

 

Two (2) LEDs (red & green) to identify 
the type of error and power 

 

Back EMF error for overspeeding 
protection 

 

Pulse signal output to indicate motor 
revolution 

 

Servo brake control allows product to 
maintain its position after run signal is 
removed 

 

Error output selection for output in 
normal or abnormal status 

 

Lead free design; RoHS compliant 

 

Low Voltage Protection reacts when 

o

 

Sustained low voltage (less than 15V 
DC) for at least 1 second 

o

 

Fluctuating voltage dropping below 15V 
DC, 5 times within 0.5 second 

 

External Direction control 

o

 

When external DIR signal is changed 
while motor is running, the motor stops 
for 0.5 second, then runs again in 
opposite direction

 

 

 

 

 

 
 
 

Summary of Contents for Power Moller 24 CBM-105FN

Page 1: ...f motor lock last for 4 seconds or thermal overload error lasts for 1 second or more Two 2 LEDs red green to identify the type of error and power Back EMF error for overspeeding protection Pulse signa...

Page 2: ...ize 28 14AWG CN3 9 PIN connector MOTOR Male Connector on Card JST S9B XH A 9P Female Connector for Wiring JST XHP 9 PIN Description 1 GND Grey 2 12V DC Blue 3 Motor phase U Red 4 Motor phase V White 5...

Page 3: ...output ERR 5 0V output PLS Wire size 28 20AWG Control Wiring Power to CN1 24V DC remains ON control motor through CN2 Press down spring clamp in connector with a small screwdriver Insert leads in prop...

Page 4: ...24V 18V or greater for PNP Output Error and Motor Pulse signals Open collector 24V 25mA or less NPN PNP selectable for Error only Servo brake mode 0 2s delay between stop signal and servo brake reacti...

Page 5: ...F 6 Error output FP type PNP NPN ON External direction signal only If a direction change signal should occur while the motor is running the motor will first stop for 0 5s Then the motor will start in...

Page 6: ...or PCB overheated Motor stops 1s after reaction Motor lock Flashes 1Hz Motor does not turn for 4s Motor stops Motor not plugged in Motor does not operate To reset an error condition Remove input signa...

Page 7: ...1 8 4 45 9 164 0 433 6 7 6 7 9 43 6 155 8 433 6 7 1 7 4 41 3 147 6 433 6 6 6 6 9 36 7 131 2 433 6 6 1 6 4 34 4 123 0 433 6 5 6 5 9 32 1 114 8 408 7 5 1 5 4 29 8 106 6 379 5 4 6 4 9 27 6 98 4 350 3 4 1...

Page 8: ...ed by the applicable mounting bracket Proper mounting is required for tube rotation Check that the Power Moller s connector is properly inserted into the driver card In belt applications check the bel...

Page 9: ...the correct connector see page 3 SW1 6 Check dip switch 1 6 is properly set for the output type you require see page 5 Error signal is discharged frequently Red LED2 If LED2 is illuminated or blinkin...

Page 10: ...ating DC voltage is 24V 10 When running long distances from a DC power supply the voltage drop during motor operation across the power bus may be significant may drop below 15V If there is a large eno...

Page 11: ...8811 Hanover Industrial Estates Fx 570 820 8838 Hanover Township PA 18706 rev13 0314 Revision History Revision Number Change 12 0508 Initial document 12 0723 Added trouble shooting section 12 0810 Cha...

Reviews: