SCREW AIR COMPRESSOR OPERATOR’S MANUAL TM356-10270
English
20
Code 1641003212 - Edition 10/2020
Starting from the main screen (see main menu):
1. Press the down button until the "user parameter" menu.
2. Press the right button to activate the submenus of the user menu
3. Press the down button to"maintenance timer reset" for
Oil Filter, Oil/Air Filter, Air Filter, Lube, Grease, Belt
4. Select Parameter & re-set to 0000.
5. Confirm the Reset.
Note: Check (15.2) MAINTENANCE SCHEDULE for componets to be changed at respective service
interval.
15.0 MAINTENANCE
BEFORE CARRYING OUT ANY MAINTENANCE JOBS IT IS OBLIGATORY TO STOP THE
MACHINE AND DISCONNECT IT FROM THE POWER MAINS.
The
maintenance jobs described in this chapter may be carried out by the user.
The more complex
maintenance jobs require professionally skilled personnel to carry out.
15.1 GENERAL INFORMATION
Routine maintenance must be carried out according to the maintenance schedule displayed on the
machine.
15.2 DRAINING CONDENSATE FROM THE OIL TANK
If the compressor work cycle contemplates long pauses during which the machine cools down, a certain
amount of condensate may collect in the oil tank. This happens, for example, when stopping overnight
or at weekends.
The condensate must be drained off every 50 hours or every week. This operation may be performed
only when the machine is cold, that is when it has been switched off for at least 8 hours.
BEFORE DRAINING THE CONDENSATE IT IS OBLIGATORY TO STOP THE MACHINE
AND DISCONNECT IT FROM THE POWER MAINS.
Proceed as follows:
-
6.
- Wait for the machine to cool down.
- Remove the panels with the key provided.
- SLOWLY turn on the tap Ref. 3 Fig. 16 and let the condensate flow out.
- When the first traces of oil appear, turn off the tap.
CONDENSATE MUST BE DISPOSED OF IN CONFORMITY WITH THE LOCAL
REGULATIONS IN FORCE.
- Check the oil level on the indicator Ref. 4 Fig. 16.
- If the oil level is low, top up as described in 15.4.
FIG. 16
1
2
5
4
3
20
www.itmtools.com.au