Installation
The following section describes how to install the lighting system.
Unpacking your Lighting System
Please examine the shipping containers and their content thoroughly upon receipt and
report any potential shipping damage to the carrier.
Tools for Installation
The following tools are suggested for mounting of the ITL flash head.
Digital multi-meter
Nut Drivers and Sockets
Compact “torpedo” level
Quick Installation Guide
The quick start guide shows how to install the IFH-1710 red/infrared LED beacon.
Remove power to existing lighting system controller by turning off circuit
breaker(s).
Verify that power has been removed by measuring all input voltages using a multi-
meter.
Remove any packaging material from inside the flash head.
Install flash head using supplied hardware.
Connect flash head power cable (see cable/wire identification table below).
Apply power to lighting system controller.
Set lighting system controller to night mode operation.
Verify that IFH-1710 flash head flashes red light at the appropriate rate.
Verify that the IFH-1710 does not alarm while operating in night mode.
All fixtures, enclosures and junction boxes must be mounted in the upright position.