23
Note
The maximum time that the ventilation unit can be in a position
other than the automatic position is limited to 24 hours. After this
period, the unit switches back to automatic mode.
4. Operation
4.1. Ventilation modes
The ventilation unit can be set to one of the following positions as
required:
●
Position 1,
low position
: when one person is present during the
day or night or when nobody is present.
●
Position 2,
middle position
: for day or night when
more than one person is present.
or
Auto mode,
automatic mode
; control based on existing
sensors (
CO2
, RH and/or PIR). The capacity is automatically
controlled between low and high position.
Auto-Night
position; regulation for the night where
the minimum position is increased.
●
Stand 3,
high level
: for when cooking, showering or bathing or
when many people are present.
The
Auto-Night setting ensures
that the minimum ventilation setting
is increased so that you are also assured of an optimal climate at
night. You can use the
Auto-Night stand
when you go to bed in the
evening. Please make sure that the window grilles are open when
using this stand.
To activate the
Auto-Night mode,
press the
Auto-button
twice on
the wireless control switch or select
Auto-Night
mode on the
controllable sensor. The
Auto-Night
setting cannot be set using the
wired three-position switch.
4.2. Controls
Various positions are pre-programmed in the ventilation unit. A
number of control switches are available for active tuning to the
correct stand/ventilation capacity:
1. Wireless control switch mer three positions and timer
function.
2. Wireless control switch with two positions, an automatic
position and timer function.
3. Wireless
CO2 sensor
with control - 230V powered.
4. Wireless stainless steel sensor with control - battery operated.
5. Wired 3-position switch for installation.
6. Spider Base, climate thermostat with three modes, an
automatic mode and a timer function.
When a Spider Connect system is installed; controllable via
the Spider climate thermostat.
A combination of the above possibilities.
You can register up to 20 wireless control switches and/or
sensors on an Itho Daalderop ventilation unit or system.
Note
The current ventilation position can always be read on the
(optional) external
CO2 sensor
or RH sensor.
Note
If several controls are used, it may happen that the ventilation
position on the wired control switch does not correspond to
the current ventilation position (because the ventilation unit
has been set to a different control or sensor position).
ä Attention
!
The
Auto-Night
mode becomes available when using
CO2
sensors.
ä Attention
!
The
Auto-Night
mode does not switch off automatically after a
certain period of time. In the morning you have to switch on
Auto
mode
(or another mode) yourself.
1
2
3
RFT-CO 2
4
R F T -R V
5