14
2.8.4.2. Filter warning CO2 sensor or RH
sensor
If the ventilation unit detects that the filter needs to be cleaned or
replaced, the unit sends a message to the controllable
CO2 sensor
,
and RH sensor (if connected). The status LED on the sensor then
flashes orange at 1 Hz. After cleaning or changing the filter, reset
the counter, see Resetting the Dirty Filter Indication on page 30.
2.8.4.3. Filter warning Spider
climate thermostat
If the ventilation unit detects that the filter needs to be cleaned or
replaced, the unit sends a message to the Spider air conditioning
thermostat (if connected). The display of the climate thermostat will
show the message Replace filter. The orange filter symbol flashes
and the ventilation symbol and the Service button illuminate
continuously. After cleaning or changing the filter, the counter must
be reset, see Resetting the dirt filter indicator on page 30.
2.8.4.4. Status LED
The appliance is equipped with a status LED. The status LED can
display the following messages:
Pattern
Function
Green
Orange
Flashes 1x/s
Flashes 1x/s
Identification
Flashes 1x/s
Login mode
Burns 6 s
Flashes 1x/s
Frost mode
Burns 5 s
Flashing 2x/s
Bypass mode
Brandt
Normal operation
Pattern
Function
Red
Orange
Flashes 1x/s
Flashes 1x/s
Error drain fan
Flashes 1x/s
Flashing 2x/s
Error
supply fan
Flashing 2x/s
Flashing 2x/s
Sensor error
outlet temperature
Flashing 2x/s
Flashing 3x/s
Sensor error
supply temperature
Flashing 3x/s
Flashes 1x/s
Sensor error
Flashes 1x/s
Filter dirt
2.8.5. Ventilation Coupling VKK
With the coupling type VKK and VKK-HB it is possible to
connect the HRU ECO 350 to the Remeha HR combi boiler the
Avanta. The purpose of the coupler is to simplify the ducting
system between the HRU ECO 350 and the boiler. Both the
ventilation installation and the boiler need a supply and an
exhaust duct to and from the outside. The VKK coupler
combines the outlet of the ventilation installation with the supply
and outlet of the boiler (2 duct system).
For example, only a supply and exhaust duct is required
for the ventilation system (up to 12 floors).
The coupling type VKK-HB (up to 40 storeys) combines the air
outlet of the ventilation system with the air supply of the boiler. Both
have a separate exhaust system (3-channel system).
VKK coupler-HB
VKK coupler
See above: Dipswitch settings on page 22.
ä Attention
!
If a VKK or VKK-HB coupling is installed, this must be set on
the ventilation unit!