5.2. Configuration settings
Note
The settings mode for the configuration settings as
well as for the user settings become available only
after the sensor has been paired with the ventilation
unit.
To enter configuration settings mode, you must first
switch off power to the sensor and then restore power to
the sensor. After that,
within 2 minutes
you must press
and hold the touch button down until the status LED
lights up blue.
Then push and hold the touch button for a minimum of 5
seconds, after which you can release it after:
●
5 to 7 seconds: pair (if applicable).
●
7 to 9 seconds: Configuration setting 1: Set type of
space. After releasing the touch button, the status
LED is lit blue and Auto /Auto Night flashes. Briefly
press the touch button:
-
Option 1: Bathroom (standard).
-
Option 2: Laundry.
Confirm your choice by pressing and holding the touch
button for 5 seconds until the status LED flashes blue.
●
9 to 11 seconds: Configuration setting 2: Setting the
duration of maximum speed of the ventilation unit.
Hold the touch button down until the status LED
lights up blue, the Auto / Auto night indicator lights
up green, and the Low Speed indicator starts
flashing. The following settings can be selected by
briefly pushing the touch button:
-
Option 1: no limit.
-
Option 2: 3 hours.
-
Option 3: 6 hours.
-
Option 4: 9 hours.
Confirm your choice by pressing and holding the touch
button for 5 seconds until the status LED flashes blue.
●
11 to 13 seconds: Configuration setting 3: Setting the
duration of other ventilation speeds. Hold the touch
button down until the status LED lights up blue, the
Auto / Auto night indicator and the Low speed
indicator light up green, and the Medium speed
indicator starts flashing. The following settings can
be selected by briefly pushing the touch button:
-
Option 1: no limit.
-
Option 2: 12 hours.
19