The device has 8 digital inputs, which are primarily designed for the detection of low-level operating and fault
conditions. This includes the monitoring of fault signals of ampli
fi
ers, monitoring of cabinet temperature by
thermostats, etc. A remote control, that is, an output follows at any point of the system the input is also pos-
sible. Each input state can be inverted for further processing by the software.
SPIDER 44/03 / SPIDER 04/03
Digital inputs
SPIDER
44/
SPIDER 04
μ
P Inputs
R
i
= 44 K
8 Logic Inputs
0.....U
IN
< 1,6 V
1.....U
IN
> 8 V
Digital outputs
SPIDER
44/
SPIDER 04
μ
P Outputs
8 Logic Ouputs
Open Collector
U
MAX
= 36 V DC
I
MAX
= 200 mA per Channel
I
TOTAL
(
∑
Out1÷Out8) = 500 mA
max 36 V DC
+
-
The device has 8 digital open collector transistor outputs. They are used for switching relays, lamps of lo-
wer power, etc. Typical applications are the display of faults, switching off other audio devices during an
announcement and more.