Safety instructions

When installing the device, the local connecting conditions, the required protective measures and all relevant 
standards have to be observed. The installation and con

fi

 guration of the ITEC Spider 44 / Spider04 must be 

performed by trained personnel only. For the con

fi

 guration the original software ITEC NetDesign has to be 

used exclusively. 
The power connection is carried out via the original power supply unit or directly to any existing 24 V DC 
power supply (emergency current). 
The power supply has on its primary side a rubber connector and is linked with an appropriate cable to the na-
tional standard AC outlet (115 - 230 volts). Please note that the ground connector of the device (audio ground 
and ground of all digital audio interfaces) is electrically not connected to the negative pole of the DC supply. 
Please observe during the installation, that no multiple connections between the ground connector of the 
device and the 24 V negative pole are put in place (see also chapter „power“). 
When installed in switch cabinets, pre-cautions need to be taken to ensure suf

fi

 cient air exchange to avoid 

overheating of the device.
When connecting to other devices (e.g.: sound sources, computers), the exact pin con

fi

 guration and the spe-

ci

fi

 cations of inputs and outputs need to be observed.

Only a connection to networks, which are compliant to IEEE 802.3 (Ethernet), is possible. Never try to open 
the device by force or by unscrewing. The product does not contain parts that can be repaired by amateurs. 
Please contact the manufacturer or a local distributor. 

Do not apply temperatures above 50 °C, humidity larger than 95% or rain to the device.

Caution:

 Before carrying out any modi

fi

 cations on the device (only by quali

fi

 ed personnel) the power supply 

has to be disconnected. The device is designed for installations in 19“ cabinets / rack / frame / housing. Impro-
per installations in furniture, cabinets or distribution systems, as well as free installation have to be avoided.

Summary of Contents for ITECNET SPIDER 04/03

Page 1: ...03 SPIDER04 03_EN_2018 07_REV_2020 02 SPIDER 44 03 SPIDER 04 03 MANUAL Designed and Manufactured by ITEC Tontechnik und Industrieelektronik GesmbH 8200 La nitzthal 300 Austria Europe SPIDER 44 03 SPID...

Page 2: ...t complex audio systems with relatively simple and well arranged operation and configuration This manual describes the hardware of the Spider 44 Spider04 shows the construction and the wiring of the v...

Page 3: ...erve during the installation that no multiple connections between the ground connector of the device and the 24 V negative pole are put in place see also chapter power When installed in switch cabinet...

Page 4: ...rnet based audio network for the simultaneous transmission of up to 64 audio channels with the highest audio quality At the same time a huge number of system data measurement data and IOs are controll...

Page 5: ...play for important device information 3 Infrared receiver function not supported 4 Rotary knob for operation of the display only SPIDER 44 44 1 2 3 4 Station ID HW Version P SW Version OnTime Input Le...

Page 6: ...3 OUT 3 2 1 3 OUT 2 P RS 485 RS 232 A B Ethernet 8 Logic Inputs 8 Logic Outputs 8 External Controls 0 dB 30 dB VCA 20 dBs 12V IN 1 P P 1 2 3 2 1 3 OUT 1 Ethernet Unit Feed CH 1 256 Get CH 1 256 A D C...

Page 7: ...hantom power is switchable per channel 12V Optional 24V or 48V phantom power is possible with a plug in module Connection is made to the included power adapter or an existing 24 V DC emergency power s...

Page 8: ...s also pos sible Each input state can be inverted for further processing by the software SPIDER 44 03 SPIDER 04 03 Digital inputs SPIDER 44 SPIDER 04 P Inputs Ri 44 K 8 Logic Inputs 0 UIN 1 6 V 1 UIN...

Page 9: ...nputs of the device or as a control variable for the output volume of any device in the network Ethernet interfaces SPIDER 44 SPIDER 04 Network B A Redundant Network Ethernet Unit The network connecti...

Page 10: ...o the serial RS 232 interface and is used to connect the devices mentioned before at distances of up to 500 meters In particular the RS 485 interface is intended for the simultaneous connection of Mul...

Page 11: ...available and therefore the wiring is different Line return The end of a line speaker wire is guided back to the device A break is detected when the transmitted signal cannot be detected at the end of...

Page 12: ...antom power 12 V optional 24 V alternatively 48 V Input impedance 6 6 kOhm Balanced outputs max output level 15 dB output impedance 300 Ohm Sound Processing Per input 2 band fully parametric equalizer...

Reviews: