background image

- 2 -

Notification

WARNING

To ensure the reliability of the equipment and the safety of personnel, please observe the following when installing,
using and maintaining:

● If any of the following conditions are found, please immediately turn off the power, plug out and quickly
contact your nearest dealer. Do not continue using this unit, which may cause a fire or electric shock.

● If you find smoke or have a strange taste from the machine.
● If water or metal falls into the machine.
● If the unit is dropped or the case is damaged.
● If the wire is damaged (wire core exposure, broken wire, etc.).

● If the machine contains high-pressure parts, in order to avoid the fire or electric shock, absolutely don’t open
the case, if any questions please inform your nearest dealer.
● Do not place cups, bowls, vases or metal and other water-filled substances on the unit. Serious spilled liquid
may cause a fire or electric shock.

● Never expose the unit to rain and any moisture or water, which may cause electric shock or fire.

● Do not place metal objects or flammable materials from the vents on the machine cover, nor place coins, which
may cause fire or electric shock.

● Do not place heavy objects on the unit to avoid personal injury or property damage when the unit is slipping.

● Make sure that the volume is turned on at the beginning of the boot, and the high volume of the boot may cause
hearing problems.

● Make sure that the volume is turned on at the beginning of the boot, and the high volume of the boot may cause
hearing problems.

● For long-term accumulation of dust to be cleaned, please inform your dealer to regularly clean the machine, so
as to avoid damage to the machine or cause a fire.

● The battery must be replaced with the same type of product and the correct installation should be made in order
to avoid electrical damage and explosion hazard.

● The product is a Class

III

device. The device must be well connected to ground. The power plug must be

connected to a power outlet with a grounding device to ensure that the equipment is fully grounded.

● This product uses a power plug or appliance input socket as a disconnecting device with the power supply, and
must be disconnected if necessary for safety reasons.

Summary of Contents for TS-0306

Page 1: ...Fully Digital Conference System User Manual TS 0306 0306A Before using this system please read this manual carefully...

Page 2: ...not place metal objects or flammable materials from the vents on the machine cover nor place coins which may cause fire or electric shock Do not place heavy objects on the unit to avoid personal inju...

Page 3: ...c shock and fire Do not touch the hands and the source with wet hands Do not spill liquid on the machine so as to avoid short circuit or fire inside the machine Do not place other equipment directly o...

Page 4: ...in this manual The software hardware and appearance of this product will be upgraded and updated continually The above changes will be made without notice Non professional maintenance personnel do not...

Page 5: ...4 5 TIMED SPEECH AND SPEECH TIMEKEEPING 10 4 6 AUDIO ADJUSTMENT 10 4 7 MICROPHONE UNIT ID AND RELATED IP ADDRESS 10 4 8 THE UNIT SUPPORTS THE ICMP PROTOCOL PING PACKETS ETC 11 4 9 CAMERA TRACKING FUN...

Page 6: ...e microphone unit 2 1 Features 1 The microphone unit adopts capacitive touch buttons which can effectively eliminate the key tapping sound for a good conference environment 2 The touch keys are waterp...

Page 7: ...web which can adjust different sound effects according to the voice characteristics of the speaker until the perfect effect is achieved 11 Support IP address sniffing function Through the PC tool it c...

Page 8: ...lity Cardioid directionality Frequency response 80Hz 16KHz Microphone input impedance 1K Sensitivity 36 1 5dB 0dB 1V Pa at 1KHz Maximum SPL 120dB THD 3 SNR 80dB A Crosstalk 70dB Dynamic Range 80dB THD...

Page 9: ...9 3 Connection diagram...

Page 10: ...ls the fire alarm and the microphone unit returns to normal 4 5 Timed speech and speech timekeeping This function needs to be controlled by the conference PC software For details refer to the PC user...

Page 11: ...n can be implemented through the conference host and the VISCA PELCD_D camera protocol is supported Users can directly connect a single camera to the conference host through 232 422 or use the camera...

Page 12: ...of the voice control mode 2 Set the no signal off time in voice control mode the chairman unit is not affected 4 13 Language switch Web setting Switch Chinese and English on the web 4 14 Sign in votin...

Page 13: ...13 4 16 View unit basic information on Web 1 Version number 2 MAC address 3 Microphone unit type...

Page 14: ...POE switch The two network ports are the same and fully adaptive The microphone units are connected hand in hand with an Cat5e or higher standard network cable Correct steps TS 0306 is required to be...

Page 15: ...15 Appendix 1 Microphone frequency response curve 2 Microphone cardioid curve...

Page 16: ...16 Fully Digital Conference System Version0 2...