Configuration
With this option another device can receive the dosed volume. Review 5.5.4 for connections.
4.2.4.4 4-20 mA output
4 - 20 mA output for log or monitoring.
Set whether the pulse output is the same as the pulse input.
Change by pressing
and confirm by pressing
ENT
Enter the % flow rate at which the 4 mA will be emitted
Enter the % flow rate at which the 20 mA will be emitted
Change by pressing
and confirm by pressing
ENT
Set whether the pulse output is the same as the pulse input.
With this option a second Dostec AC can be driven by the same
flowmeter in proportional (%) mode.
Enter the volume of product dispensed
for each product.
Change by pressing
and
confirm by pressing
ENT
4.2.4.5. Maintenance
In the Maintenance menu, the status of components subject to wear
can be viewed using the status bars.
A warning will appear on the main screen at the end of the useful life
of a component.
The status bars in the maintenance menu show the remaining life of
each component and display a
!
when the bar becomes empty, with
this being the recommended time to replace the component.