20
DOSING MODE
Mode:
Low Pulsation
LP
Max.Flow 84,0 l/h
ENT
DOSING MODE
Mode:
Low Flow
LF
Min. Flow 2,40 l/h
DOSING MODE
Mode:
Slow Suction
SS
Max.Flow 120 l/h
Configuration
4.2.2.2 Low flow
The Low Flow mode (LF) allows dosing to be paused during the discharge cycle, extending the dosing
time and therefore reducing the flow to as little as 1%.
The other modes allow the flow to be reduced to as little as 10%.
4.2.2.3 Slow suction
The Slow Suction mode (SS) reduces the speed during the suction cycle in order to improve precision in
the dosing of viscous liquids, since it reduces the risk of cavitation and incomplete filling of the head. The
maximum flow is reduced by 50%.
4.2.2.4 Low Pulsation / Low Pulsation
Low Pulsation mode (LP) lengthens the impulse cycle time in order to minimize the effect of pulsating flow
and reduce overpressures caused by long pulses.
The maximum flow is reduced depending on the reducer model (frequency).
Change by pressing
and confirm by pressing
ENT
Change by pressing
and confirm by pressing
ENT
Change by pressing
and confirm by pressing
ENT
Frequency
Max. Flow Reduced to
1
55%
2
55%
3
50%
4
35%