10
B
E
F
A
C
G
D
ENT
ESC
L/H
L/H
4
3
25
Bars
1
1120-
1160-
1240-
1200-
l/h
GPH
270-
58
43
29
72PSI
14
1080-
280-
290-
300-
310-
320-
-
73-AC3D44-D163
1040-
l/h
620 -
660 -
700 -
4
3
2
1
GPH
170-
180-
190-
200-
210-
220-
58
43
29
Bars
6
5
7
PSI
87
72
101
14
740 -
780 -
820 -
73-AC3D43-D163
Configuration
4. OPERATION
The rotational motion of the motor is transmitted by the reducer, which consists of two major components,
the pinion (A) and the ring gear (B). The pinion and the ring gear are linked to a shaft with an eccentric
bearing (C) that pushes the shaft (D) which is throated to the diaphragm or the piston (E). The return
movement is made by a spring (F).
A high resolution encoder (G) checks the instantaneous position and speed and allows the Advanced
Control Unit to do a close loop adjustment for torque and rotation speed.
By changing the motor speed and depending on the operation mode selected in the Advanced Control
Unit, the dosing pump adjusts the flow to the required value within the range from 10 to 100% of the rated
flow.
EQUIPMENT DESCRIPTION
LCD screen
Keyboard
Confirm
Exit without
confirming
Increase/decrease value
Scroll left
Scroll right
Summary of Contents for DOSTEC AC
Page 1: ...DOSTEC AC ENGLISH ...