Safety Symbol and Message Conventions

Safety  symbols and messages  described  below are used in this manual  to prevent  bodily injury and  property 
damage  which  could  result  from  mishandling.  Before  operating  your  product,  read  this  manual  first  and
 understand the safety symbols and messages so you are thoroughly aware of the potential safety 

Indicates a potentially hazardous situation which, if mishandled, could
result in death or serious personal injury.

Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.

When Installing the Unit

   Do not  expose  the unit   to rain or an  environment
   where it may be splashed by  water or other liquids, 
   as doing so may result in  fire or electric shock.

   Use the unit only with the voltage   specified  on the
   unit.  Using  a  voltage  higher  than  that  which  is
   specified may result in fire or  electric shock.

   Do not cut, kink, otherwise damage   nor modify the
   power  supply  cord.  In  addition,  avoid  using  the
   power cord in close proximity to heaters,  and never
   place heavy objects -- including the unit   itself -- on 
   the  power  cord,  as  doing so may result  in  fire or  
   electric shock.

 Be sure  to replace  the unit's   terminal  cover  after
 connection  completion.  Because  high  voltage   is
 applied to the speaker terminals, never touch these  
 terminals to avoid electric shock.

 Be  sure  to  ground  to  the  safety   ground  (earth)
 terminal to avoid electric shock. Never   ground to a 
 gas pipe as a catastrophic disaster may result.

 Avoid  installing  or  mounting  the  unit  in  unstable
 locations, such  as   on a rickety  table   or  a slanted
 surface.  Doing  so  may  result  in  the  unit   falling
 down,   causing   personal   injury  and/or  property 
 damage.

When the Unit is in Use

   Should  the  following  irregularity  be  found  during 
   use, immediately switch  off  the  power, disconnect
   the  power  supply   plug  from  the  AC  outlet  and 
   contact  your  nearest  

  dealer. Make no further

   attempt  to operate the unit in this   condition as  this
   may cause fire or electric  shock.
     If  you  detect  smoke  or  a strange  smell coming
     from the unit.
     If water or any metallic object gets into the unit
     If the unit falls, or the unit case breaks
     If the power supply cord is damaged (exposure  of
     the core, disconnection, etc.)
     If it is malfunctioning (no tone sounds.)

   To prevent  a fire or electric  shock, never open  nor
   remove  the  unit  case  as  there  are  high  voltage 
   components  inside  the  unit.  Refer all servicing to
   your nearest  

 dealer.

ITC

ITC 

 Do  not  place  cups,  bowls,   or other containers  of
 liquid  or  metallic  objects on top  of the unit. If  they 
 accidentally spill  into the unit, this may cause  a fire 
 or electric shock.

  Do   not   insert    nor   drop    metallic    objects   or 
  flammable  materials  in  the   ventilation slots  of the
  unit's  cover,  as  this  may  result   in  fire  or electric
   shock.

3

1. SAFETY PRECAUTIONS

T-218

Summary of Contents for T-218

Page 1: ... instructions in this manual to obtain the optimum resultsfrom this unit We also recommend that you keep this manual handyfor future reference PAGING MIC CONSOLE OPERATION MANUAL AUDIO AUDIO PUBLIC ADDRESS SYSTEM T 218 ...

Page 2: ...CTIONS 4 1 Front Panel 6 4 2 Rear Panel 7 5 5 1 Usage ways 8 5 2 Address code setting 8 5 3 Broadcast music play 8 5 4 State light 8 5 5 Operation attentions 8 5 6 Wiring connection attentions 9 5 7 Paging selector address code setting 9 6 APPLICATIONS 10 7 SPECIFICATIONS 12 8 DIMENSIONAL DIAGRAM 13 OPERATION ...

Page 3: ...n fire or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is applied to the speaker terminals never touch these terminals to avoid electric shock Be sure to ground to the safety ground earth terminal to avoid electric shock Never ground to a gas pipe as a catastrophic disaster may result Avoid installing or mounting the unit in unstable ...

Page 4: ...oty smoke or steam as doing otherwise may result in fire or electric shock When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause injury and or damage Make sure that the volume control is set to minimum position before power is switched on Lo...

Page 5: ...up to 16 MICS and 160 paging zones working with 10 zone paging selector One audio input and one MIC output Mute function and built in chime The simple configuration of 10 zones paging system is T 6212 10 zone paging selector works with T 6202 10 zone speaker selector and T 218 remote paging MIC The max is 160 zones of 16 remote paging MIC T 218 and 16 10 zone paging selector T 6212 T 218 All ten z...

Page 6: ...n zones switch button 9 ALL ZONES All zones switch indicator 10 TEN ZONES All zones switch button 11 CH1 CH10 Zone switch button 12 CH1 CH10 Zone switch indicator 13 MIC MIC balance input 1 UP DOWN 2 MIC ON OFF MIC ON OFF 4 ADDRESS LED screen 5 CHIME ON CHIME ON Up select button Down select button MIC switch indicator 3 MIC switch button Chime state indicator 6 Chime triggering button 7 TEN ZONES ...

Page 7: ...er shut down 15 AC FUSE 16 220V 50Hz AC POWER INPUT 17 COM Remote jack 18 OUTPUT Line output Non equilibrium type the output of all input signals 19 Line Balanced inputs 20 CHIME VOL Chime volume control 21 MIC VOL MIC volume control LINE IN 4 2 REAR PANEL 14 15 T 218 16 17 18 19 20 21 220V ...

Page 8: ...Chime music is stopped 3 ZONE STATE LIGHT Light it means the zone is off Die it means the zone is on Slowly interval 0 5seconds flash it means the current operation is invalid the called unit is not exist or wrong connection of the control wire code consoles processing the on or off operation to the zone Quickly interval 0 5seconds flash it will eliminate all the current states After press the but...

Page 9: ...e drawing The first from 1 10 The ninth from 81 90 from 11 20 The tenth from 91 100 The third from 21 30 The eleventh from 101 110 The fourth from 31 40 The twevle from 111 120 The fifth from41 50 The thirteenth from 121 130 The sixth from 51 60 The fourteenth from 131 140 The seventh from 61 70 The fifteenth from 141 150 The Eighth from 71 80 The sixteenth from 151 160 The second Definition Defin...

Page 10: ...K OF ELECTRIC SHOCK DO NOT OPEN RISQUE DE CHOC ELECTRICUS NE PAS QUVRIR AVIS PUBLIC ADDRESS SYSTEM SERIAL NO A B ALARM OUT SWITCH OUT ALARM IN 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 ADDRESS TAG REMOTE OUT REMOTE IN CHIME VOL MIC 2 IN LINE 1 IN LINE 2 IN AUDIO OUT 220V 50Hz T1AL250V RISK OF ELECTRIC SHOCK DO NOT OPEN RISQUE DE CHOC ELECTRICUS NE PAS QUVRIR AVIS PUBLIC ADDRESS SYSTEM SERIAL NO A ...

Page 11: ... RISK OF ELECTRIC SHOCK DO NOT OPEN RISQUE DE CHOC ELECTRICUS NE PAS QUVRIR AVIS PUBLIC ADDRESS SYSTEM SERIAL NO T 6600 Intelligent controller The sixteentg T 218 The second T 218 The first T 218 Whit e oran ge Wh ite blo wn Blo wn Oran ge Whit e oran ge Wh ite blo wn Blo wn Oran ge White orange Blue White blown Blown Orange White blue White green Green Connection method Netwire making method Netw...

Page 12: ...PTION POWER REQUIREMENTS GROSS WEIGHT MIC 600 Ohms 10mV Unbalanced LINE 10KOhms 400mV Unbalanced MIC 100Hz 15KHz LINE 20Hz 18KHz MIC input 80dB Line input 90dB Chime MIC vol controls 160 channel selectors Chime button powe switch Power LED 10 paging channel LEDs 110 120AC or 230 240V AC 50 60Hz 24DC optional AC fuse 1A 484X360X88 T 218 10W Balanced 2 2Kg 2 6Kg 12 T 218 ...

Page 13: ...ONAL DIAGRAM 13 T 218 50 Over 50 Over Over 50 UNIT mm UNIT mm 176 144 19 19 144 144 ADDRESS CH 6 CH 1 CH 7 CH 2 CH 8 CH 3 CH 9 CH 4 CH 10 CH 5 TEN ZONES ALL ZONES MIC MIC ON OFF CHIME ON PAGING MIC CONSOLE T 218 ...

Page 14: ...AUDIO AUDIO Guangzhou ITC Electronic Technology Limited Http www itc pa com cn PUBLIC ADDRESS SYSTEM 2008 03 Version1 1 ...