Green Heating Technology
43
Signal
Probable causes
Suggested solutions
43
Over-temperature
of water on system
return
The water that returns to the boiler from the heating system is too
hot: this may be an effect of a malfunction of the system, and any-
way this can cause a too high temperature of the flue and damage
the flue system. Before this happens, a suitable safety protection
has triggered.
Wait 20-30 minutes to let the boiler and the system cool down, then
turn the knob
on the unlock
position until the red lamp
turns off, then bring again the knob in the previous position. It is
impossible to restart the boiler before the cooling of the system. If
the block happens again, please call a qualified technician.
46
Cabling configura-
tion error.
See alarm
33
.
– –
(??)
The “Hot Water”
knob
is on a
position reserved
to the techni
-
cian:
or
service
.
Turn the knob back along the scale
.
– –
(??)
RED
GREEN
it has been started,
by mistake (moreo
-
ver very improb
-
able), a procedure
reserved to the
Technician
In order to avoid malfunctions, do the following as soon as possible:
f
turn the knob
on the off/unlock
position;
f
turn the "Hot Water" knob
along the scale
;
f
turn the knob
on the normal working position (Summer
or
Winter
along the scale
).