Green Heating Technology
35
HEAT INPUT
FAN RPM
INDICATIVE
DISPLAY
VALUE
kW
kcal/h
Natural gas
G20
Commercial
Propane G31
City Ma
x 32 K
MIN. 6.9
5934
1500
1600
0
9.5
8170
1930
2030
10
12.0
10320
2360
2460
20
14.5
12470
2790
2890
30
17.0
14620
3220
3320
40
19.5
16770
3650
3750
50
22.0
18920
4080
4180
60
24.5
21070
4510
4610
70
27
23220
4940
5040
80
29.5
25370
5370
5470
90
MAX. 32.1
27606
5800
5900
99
Electronic settings
Accessing the main board
To access the main board:
Cut off the electrical supply to the boiler. Re
-
store the supply after having closed the contol
panel rear cover.
f
unscrew the screws
1
and remove the back cover
of the control panel.
Main board settings
The boiler is equipped with a Microprocessor modulation board, featuring a 6-microswitch array
(SW1÷SW6) which allow to make personalizing actions for the boiler’s functioning as described in the
following table.
Disconnect the power supply
before approaching the microswitches. Restore the power supply
only after you have closed the back cover of the control panel.
Changes to microswitches status have no effect until the boiler is electrically supplied (they are
red during the board startup, when the supply is connected).
S1
M15
M4
M2
M16
M6
M1
S1
28
27
26
25
24
23
22
21
39
38
7
8
9
10
1
2
3
4
5
6
68
69
70
71
72
73
74
75
SW1
SW6
ON
ON
SW 1
ON
OFF
SW 2
SW 3
SW 4
SW 5
SW 6
00014 00