In case you foreseen to discharge the combustion products through
a chimney
(for
single user) or
a common flue
(for multiple users) the part of the evacuation system
(the chimney or the flue) to which the outlet duct of the condensing boilers is con
-
nected,
must be declared suitable for this purpose by its producer
. In case of com-
mon chimney, keep in mind the laws in force regarding the typologies and rates of
users.
Don't lean the flue pipe into the chimney, but stop it before the inner surface of the
chimney. The axis of the flue pipe must intersect the axis of the chimney or of the
flue duct.
In general situations the
evacuation systems
of the combustion products
must be
properly declared suitable from the producer of the same system
for wet function
-
ing,
or must be supplied by the appliance’s producer
(gas boiler).
If the chimney (or the flue) were not suitable, it would be indispensable, to use it,
to canalise it through specific ducts, so for example through the original flue acces
-
sories .
00044 00
Flue duct
or chimney
NO
NO
YES