![Italtherm 18 K Instruction Download Page 14](http://html1.mh-extra.com/html/italtherm/18-k/18-k_instruction_2094858014.webp)
Green Heating Technology
14
f
press the button
: to get to the
page
(infor-
mation about the
boiler settings
):
•
heating,
DHW: they support the numeric in
-
dications;
•
indicator number
1
: Primary CH flow temperature
set value, or, if outdoor probe
is installed, ig-
nore this value;
•
indicator number
2
: DHW temperature (set tempera
-
ture)
•
indicator number
3
: Secondary CH flow (set temperature)
f
Press the button
: the display shows the
page
: information which are referred to the
thermoregulation (if the outdoor probe
is installed only).
•
CH system,
zone/s,
outdoor probe: they support the numeric indications.
•
indicator number
1
: CH flow temperature to the primary zone (shown when the request is on).
The temperature is calculated on the base on the outdoor probe temperature according to its
kd
curve setting
•
indicator number
2
: outdoor probe
kd
curve number
•
indicator number
3
: CH flow temperature to the secondary zone (shown when the request is on).
The temperature is calculated on the base on the outdoor probe temperature according to its
kd
curve setting
•
indicator number
4
: Outdoor temperature felt by the outdoor probe. If the value is – 9 it means
that the outdoor temperature is 9° C below 0° or even lower.
f
Press the button
: the display shows the
page
: information which are referred to the
solar
:
•
indicator number
1
: flow temperature of the fluid from the solar panel
•
indicator number
2
: functional code (technical information)
•
indicator number
3
: temperature of the solar storage - upper sensor
•
indicator number
4
: temperature of the solar storage - lower sensor
f
Pressing the buttons
and
it is possible to turn the pages onward or backward;
f
Press the button
to exit the INFO menu. Anyway, after 15 minutes the boiler automatically exits
the menu.
Holiday menu
Note: if the clock has not been set yet (see "Hour and day setting" on page 11) this function cannot be
used.
The user can decide to keep the boiler on OFF mode as many days as he wants. After that, the boiler
automatically returns in winter mode (or, if the optional Remote Control is installed, this latter returns
in the mode it was in the moment of the activation, while the boiler returns in Summer mode to allow
the correct work of the Remote Control).
f
The boiler must be set on OFF mode (not in winter or summer mode), and press the button
for
at least 5 seconds;
f
on the left side of the display the symbol
and “Ho” will appear as well as on the right side a value
number;
00148 A 01
1