u.m.

Technical data

Supply

Nominal heat input. (Qn)
Red. heat input.
Nominal heat output (Pn)
Red. heat output
Efficiency
Nominal supply pressure
Nominal nozzle pressure
Reduced nominal nozzle pressure
Gas consumption (15

°

C)

Type of appliance
Fuel category
Efficiency class / NOx
Burner nozzles

Pilot nozzles

MAX/MIN heated volume (approximate)
Quantity of heated air (approximate)
Power supply: 3 batteries A
Power input in operation
Degree of protection
reduced Gas consumption G20 (15

°

C)

reduced Gas consumption G30/G31 (15

°

C)

Gas connection pipe
Gas valve to burner supply pipe
Intake/exhaust pipes
Batteries
- Remote control
- Receiver unit

-

kW
kW
kW
kW

%

mbar
mbar
mbar

m

3

/h

kg/h

nr

mm

nr

Code

m

3

m

3

/h

V -

W

-

m

3

/h

kg/h

-
-

Ø mm

nr
nr

methane

G20

5,6

4,30
4,99

3,7

89,2
20,0
12,0

7,0

0,592

I 2H

1 / 5

1

1,98

1

35

230

92

IP20

0,454

propane

G31

5,6

4,30
4,99

3,7

89,2
37,0
36,8
20,0

0,435

I 3P

1 / 5

1

1,10

1

25

230

92

IP20

0,334

80

Ø 10mm

Ø 8mm

54/54

2 x 1,5V AA

4 x 1,5V A

methane

G20

9,0
7,0

8,14

6,1

  90

20,0
12,0

7,3

0,952

I 2H

1 / 5

2

1,80

1

35

230

92

IP20

0,739

propane

G31

9,0
7,0

8,14

6,1
90

37,0
36,8
20,0

0,689

I 3P

1 / 5

2

1,05

1

25

230

92

IP20

0,543

130

Model 1 side
Model 2 sided

IF08A3
IF08A2

IF13A3
IF13A2

C12 - C32 - C42 - C52

DESCRIPTION

Code

Mod. 80, casing with installation in middle of room

Mod. 80, casing with wall installation short side

Mod. 80, casing with wall installation long side (RH controls)

Mod. 80, casing with wall installation long side (LH controls)

Mod. 130, casing with installation in middle of room

Mod. 130, casing with wall installation short side

Mod. 130, casing with wall installation long side (RH controls)

Mod. 130, casing with wall installation long side (LH controls)

90

 curves Ø 54mm pipe union

Extension Ø 54mm L = 500mm

Extension Ø 54mm L = 1000mm

90

 curve Ø 54mm cast

135

 curves Ø 54mm

Outer protection grille "GP" for separate end piece Ø 54mm

Outer protection grille "GPu" for combined end piece Ø 54mm

Recessed screen "SDP" for separate end piece Ø 54mm

Stack for pipe Ø 54mm

INSULATION for pipe Ø 54mm L = 1000mm (pack of 4 pcs.)

Inlet/Outlet end piece Ø 54mm L = 6 cm

SPECIAL OUTLETS KIT (pipes from inside the room) Ø 54mm

CHIMNEY Weathering, INCLINED ROOF Ø 54mm

CHIMNEY Weathering, FLAT ROOF Ø 90mm

COAXIAL END SECTION KIT Ø 110 mm (ROOF installation) Ø 54mm

Special Pipes Kit Ø 54 mm (2 single term.)

70006085 00

70006090 00

70006095 00

70006100 00

70006110 00

70006115 00

70006120 00

70006125 00

70000370 00

70000390 00

70000380 00

70000755 00

70000375 00

70000350 00

70000610 00

70000365 00

70000740 00

70000850 00

70000465 00

TP5410A5 00

70000725

70000726 00

70000445 00

TP54SP 00000

TECHNICAL DATA 

ACCESSORIES

Summary of Contents for IF08A2

Page 1: ......

Page 2: ...ectromagnetic directive compatible 89 336 CEE Low tension directive 73 23 CEE 0694 RANGE 80 insert IF08A3 M1000 1 side PEBBLES IF08A3 M2000 1 side SMALL WOOD IF08A2 M1000 2 sided PEBBLES IF08A2 M2000...

Page 3: ...urer 3 GENERAL WARRANTY Our appliances are covered by a SPECIFIC WARRANTY starting on the date of validation by the Authorised After Sales Service of your area whose address you can find on our websit...

Page 4: ...re 27 Wood wall protection KIT 28 Power connections 29 Gas supply connection 29 TECHNICAL ASSISTANCE Operations to be performed before initial start up 30 First start up 30 Control panel malfunction 3...

Page 5: ...igned The Manufacturer disclaims any contractual and non contractual liabi lity for injuries caused to people or animals and damage to things due to installation errors wrong settings bad maintenance...

Page 6: ...ccur outside the installation premises In view of their small size they can be installed in very compact spaces and ensure a greater well being of the heated environment The natural convective movemen...

Page 7: ...3 14 15 16 17 18 19 21 22 23 26 27 9 23 28 29 14 30 24 19 31 32 33 5 25 33 20 environment probe 21 pressure switch 1 22 control unit 23 gas inlet pipe 24 pressure switch 1 pressure point 25 combustion...

Page 8: ...IF13A2 C12 C32 C42 C52 DESCRIPTION Code Mod 80 casing with installation in middle of room Mod 80 casing with wall installation short side Mod 80 casing with wall installation long side RH controls Mo...

Page 9: ...PS2 C52 SAS VC VT CN T1 VT TA BL WH RD SC EA ER EV1 F CL EV2 L N PS TL1 EP SPLIT ROOM PROBE COMBUSTION FAN TANGENTIAL FAN CONNECTOR POWER TERMINAL TANGENTIAL FAN IGNITION TRANSFORMER BLUE WIRE WHITE W...

Page 10: ...parameter 5 Wireless On button switch press and hold 2 seconds LED 4 starts to blink to recognize the Wireless waiting at MAX 60 seconds after which it automatically reactivates the manual control 5b...

Reviews: