The appliance can be identified by means of:
- the packaging label
showing the name of the product, the code, the serial
number and the type of gas that can be used.
- The Technical Plate
showing the serial number, the model and the main
technical-performance data.
- The gas type plate
Showing the name of the gas for which the appliance
has been set and regulated. If the type of gas is
changed, this plate must be replaced with that of the
new gas!
Spare parts and/or technical jobs require the
exact identification of the associated model
of appliance.
Tampering with, removing or the absence of the
Technical Plate, etc. does not allow the exact
identification of the product, making any installa-
tion and maintenance job difficult.
Independent gas appliances for heating environ-
ments.
They feature an atmospheric burner with combustion
chamber TYPE C12 – C32 – C52 – C62, sealed with
respect to the installation premises, utmost guaran-
tee of safety because no exhaust or fuel fumes enter
the premises.
The suction of the combustion air and discharge of
combustion products occur outside the installation
premises.
In view of their small size, they can be installed in
very compact spaces and ensure a greater well-
being of the heated environment.
The natural convective movement permits quick hea-
ting of the environments from when the appliance is
switched on.
An electronic board controls all the main functions of
the appliance and automatically interrupts the gas
supply in case of a fault.
The control panel features: power On/Off to applian-
ce, manual or automatic start or stop, On/Off
Wireless, heat output selection, room temperature
adjustment and restoring of operating conditions
after any fault.
The appliances are factory set, to operate
with Natural Gas, but are also available for
LPG (G30/G31).
This type of appliance can be transformed from
Natural Gas to LPG and vice versa.
The gas type and pressure used for operation are
shown on the technical data plate affixed to the
appliance.
Do not change the factory settings of the gas
control unit or receiver before installation. The
burner and pilot light are factory set by the
Manufacturer.
The fireplace must be connected to the gas type
shown on the burner. Never ever connect a
Natural Gas burner to the LPG supply or vice
versa.
6
GENERAL
APPLIANCE DESCRIPTION
IDENTIFICATION