Italkero IF08A2 User, Installation And Technical Assistance Download Page 7

7

GENERAL

1 - hot-air outlet
2 - frame
3 - heat exchanger
4 - detection and ignition electrodes
5 - burner unit
6 - door with glass
7 - condenser
8 - hot-air centrifugal fan
9 - power On/Off
10 - manual control unit
11 - gas supply tap
12 - antenna radio Wireless
13 - technical data plate
14 - combustion fan
15 - pressure switch 2* pressure point
16 - fume exhaust
17 - combustion air inlet
18 - ignition transformer
19 - power supply plug

2

35

37

36

38

3

4

5

6

8

9

1

10

11

12

7

13

14

15

16

17

18

19

21

22

23

26

27

9

23

28

29

14

30

24

19

31

32

33

5

25

33

20 - environment probe
21 - pressure switch 1
22 - control unit
23 - gas inlet pipe
24 - pressure switch 1 pressure point
25 - combustion air pipe
26 - manual controls
27 - mains gas inlet connection
28 - pressure switch 1 pressure point
29 - pressure switch  2* pressure point
30 - safety thermostat
31 - upstream pressure point
32 - gas valve
33 - downstream pressure point
34 - anti-explosion door
35 - digital wireless control
36 - display panel
37 - integrated environment heat probe
38 - data setting key

25

* Pressure switch 2 is present in the
accessory kit for separate terminals.

20

optional

STRUCTURE

Summary of Contents for IF08A2

Page 1: ......

Page 2: ...ectromagnetic directive compatible 89 336 CEE Low tension directive 73 23 CEE 0694 RANGE 80 insert IF08A3 M1000 1 side PEBBLES IF08A3 M2000 1 side SMALL WOOD IF08A2 M1000 2 sided PEBBLES IF08A2 M2000...

Page 3: ...urer 3 GENERAL WARRANTY Our appliances are covered by a SPECIFIC WARRANTY starting on the date of validation by the Authorised After Sales Service of your area whose address you can find on our websit...

Page 4: ...re 27 Wood wall protection KIT 28 Power connections 29 Gas supply connection 29 TECHNICAL ASSISTANCE Operations to be performed before initial start up 30 First start up 30 Control panel malfunction 3...

Page 5: ...igned The Manufacturer disclaims any contractual and non contractual liabi lity for injuries caused to people or animals and damage to things due to installation errors wrong settings bad maintenance...

Page 6: ...ccur outside the installation premises In view of their small size they can be installed in very compact spaces and ensure a greater well being of the heated environment The natural convective movemen...

Page 7: ...3 14 15 16 17 18 19 21 22 23 26 27 9 23 28 29 14 30 24 19 31 32 33 5 25 33 20 environment probe 21 pressure switch 1 22 control unit 23 gas inlet pipe 24 pressure switch 1 pressure point 25 combustion...

Page 8: ...IF13A2 C12 C32 C42 C52 DESCRIPTION Code Mod 80 casing with installation in middle of room Mod 80 casing with wall installation short side Mod 80 casing with wall installation long side RH controls Mo...

Page 9: ...PS2 C52 SAS VC VT CN T1 VT TA BL WH RD SC EA ER EV1 F CL EV2 L N PS TL1 EP SPLIT ROOM PROBE COMBUSTION FAN TANGENTIAL FAN CONNECTOR POWER TERMINAL TANGENTIAL FAN IGNITION TRANSFORMER BLUE WIRE WHITE W...

Page 10: ...parameter 5 Wireless On button switch press and hold 2 seconds LED 4 starts to blink to recognize the Wireless waiting at MAX 60 seconds after which it automatically reactivates the manual control 5b...

Reviews: