REMARKS ON INSTALLATION
Note that:
• the appliance must be installed by authorised
technical personnel
• the appliance must be installed and operated
in compliance with local and national laws and
European regulations
• if installed in a condominium, the appliance must
be approved by the administrator.
Here are a few general instructions, although these do
not obviate the need to comply with local regulations
and do not affect the installer’s liability for the
installation.
INSTALLATION
FLUE SYSTEM
(Fumes duct, flue and chimney pot)
This chapter has been drawn up pursuant to European
regulations EN 13384, EN 1443, EN 1856 and EN
1457. The installer must observe both these and any
other local regulations. This manual does not in any
way substitute such regulations.
The product must be connected to a flue system which
ensures that the fumes produced by combustion are
expelled in complete safety.
Before positioning the appliance, one must check that
the flue is suitable.
FUMES DUCT, FLUE
The fumes duct (which connects the combustion
chamber smoke outlet with the flue) and the flue itself
must, among other regulatory requirements:
• receive the fumes from a single product (the outlets
of multiple appliances may not be conveyed into
a single flue)
• have a mainly vertical course (no horizontal
sections and bends of over 45° are allowed)
• have no downwards sloping sections
• have a preferably circular internal cross section
and nevertheless with a ratio of the sides of less
than 1.5
• terminate at roof level with a proper chimney pot:
the flue may not discharge directly on the wall
or into an enclosed space, even if the space in
question is open to the sky
• be made of material with rated fire reaction class
A1 as per UNI EN 13501 or analogous national
regulations
• be certified, with a chimney plate if metal
• keep the initial section.
Checking the suitability of the installation
space
• The room must have a volume of at least 40 m
3
• The appliance may not be installed in a bedroom,
bathroom or in the same room as other equipment
which draws air for combustion from the room
itself, or in any area with an explosive atmosphere.
Any extraction fans operating in the same room/
area of the product, may affect its draw
• In Italy, check the compatibility pursuant to UNI
10683 and UNI 7129 in the presence of gas-fired
products
• The floor must be able to bear the weight of the
product and its accessories.
Protection from heat and safety
clearances
The surfaces of the building adjacent to the product
must be protected against overheating.
The insulation to be used will depend on the type of
surface in question.
Observe the following minimum distance from
inflammable
materials
- 10 cm from the non-glass rear of the appliance
- 150 cm from the glass sides. Do not place any
inflammable materials at shorter distances.
Power lines
no power lines must be present in the walls
and in the ceilings within the recessed area
of the product
PLEASE NOTE:
If the fireplace is not level there may
be problems with the door’s sliding
movement.
®