ENGLISH
30
HYDRAULIC CONNECTIONS
NOTE:
The installer must assess the possible need for an additional expansion tank, depending on the type of system being serviced
WARNING:
during the production of domestic the power to the radiators decreases temporarily.
ACCESSORIES:
In the diagrams referred to in the previous pages the use of accessories available from the Edilkamin catalogue has been
assumed.
Individual spare parts are also available (exchanger, valves, etc). For information, please contact your local dealer.
1. START UP (DEALER)
Make sure the plumbing system has been properly executed and is equipped with an expansion tank which is sufficient to gua-
rantee safety. The presence of the tank built in to the boiler-stove does NOT guarantee adequate protection from thermal
expansion experienced by the water inside the system.
Power on the boiler-stove electrically and run the test cold.
Carry out the filling of the system through the inlet valve (it is recommended that you maintain a pressure of approximately1 bar)
During the loading phase, "bleed" the pump and open the manual vent (see page 32)
This operation must also be performed subsequently on a periodic basis.
System as the sole source of heating, producing household hot water with a boiler.
This layout is indicative only: your plumber will be responsible for the ultimate installation.
Storage system for producing household hot water with an IDROKIT water kit combined with a boiler.
This layout is indicative only: your plumber will be responsible for the ultimate installation.
LEGEND
ACS:
Household hot water
AL:
Water supply input
B:
Boiler
C:
Fill/Top up
EV2:
2-way electro-valve
EV3:
3-way electro-valve
NA:
Normally Open
NC:
Normally Closed
GR:
Pressure reducer
MI:
System in
P:
Pump (circulation)
RA:
Radiator
RI:
System return
S:
Drain
TS:
Boiler-stove
V:
Spherical valve
Vec:
Closed surge tank
VSP:
Safety valve
LEGEND
ACS:
Household hot water
AF:
Cold water
AL:
Water supply input
C:
Fill/Top up
CE:
Electronic control unit
EV:
3-way electro-valve
NA:
Normally Open
NC:
Normally Closed
GR:
Pressure reducer
Ja:
Automatic status device
Jm:
Manual status device
MI:
System in
MT:
Thermostatic mixer
P:
Pump (circulation)
RA:
Radiators
RI:
System return
S:
Drain
SC30:
30-plate exchanger
ST:
Temperature probe
TC:
Contact thermostat
TS:
Boiler-stove
V:
Spherical valve
Vec:
Closed surge tank
VR:
Non-return valve
VSPT:
Pressure-temperature safety valv
Components inside the boiler
-stove
manifold
manifold
Components inside the boiler
-stove