background image

Infineon DAP/DAPE Active Probe

User Manual

V2.7

Summary of Contents for IC57163

Page 1: ...Infineon DAP DAPE Active Probe User Manual V2 7 ...

Page 2: ...ll rights are reserved Duplication of these documents is allowed for personal use In all other cases written consent from iSYSTEM is required iSYSTEM AG All rights reserved All trademarks are property of their respective owners iSYSTEM is an ISO 9001 certified company www isystem com ...

Page 3: ... Connectors and Position 10 ECU14 DAP 10 pin 1 27mm Converter 11 MEDC17 DAP 10 pin 1 27mm Converter 12 ERF8 DAP 22 pin Converter 13 Active Probe and the iC5700 Connecting Guidelines 14 Connecting Active Probe to the Target 15 Setting Debug Interface Voltage Levels 17 DAP and DAPE configuration 18 Further Active Probe Settings 19 Accessories 21 User Notes 22 ...

Page 4: ... provide software tools to perform advanced worst time execution analysis based upon the data winIDEA can export When a Real Time Operating System RTOS is in use the state of the RTOS and its tasks can also be visualized More information isystem com winideaide testIDEA testIDEA environment simplifies the development of unit tests for embedded applications By making use of the winIDEA environment t...

Page 5: ...o avoid potential damage caused by any voltage difference between the device and the target system Use proper overvoltage protection Please ensure proper protection to avoid exposing the BlueBox device or the operator to overvoltage surges e g caused by thunderstorm mains power Do not operate without cover Do not operate the device with cover removed Avoid circuit and wire exposure Do not touch ex...

Page 6: ...e Probe kit is delivered with the following components Infineon DAP DAPE Active Probe Two 10 pin 1 27mm 10cm long ribbon cables 1m FNet Micro Cable Ordering code IC57163 Ordering code IA10PIN10PIN127 AP Ordering code BB FNETMICRO 100 User Manual ...

Page 7: ...RATION Communication interface to BlueBox iSYSTEM proprietary FNet Debug signal valid input voltage range 3 3V max 3 6V Power consumption Max 1 5W dependent on operation mode PROTECTION Debug signals 33 Ohm series termination protection resistors ESD protection devices DAP1 3 and DAPE1 3 10k Ohm pull down DAP_RESET 1k Ohm pull up 33 series termination protection resistor VREF 1k Ohm input impedanc...

Page 8: ...Operation Device overview ...

Page 9: ... I O Ground GND 9 10 NC Not Connected 10 pin DAPE pinout Signal direction definition O Output from the Active Probe to the target microcontroller I Input to the Active Probe from the target microcontroller C FNet Micro connector that connects the Active Probe to the iC5700 BlueBox The FNet Micro cable is delivered with the Active Probe D The indicator light provides the status of the Active Probe ...

Page 10: ...ed The goal should be to link the Active Probe to the target hardware via non twisted and when DAPE is used parallel ribbon cables IA10PIN10P AP CUST custom length DAP interface ribbon cable Optionally a longer ribbon cable can be ordered under the ordering code IA10PIN10P AP CUST The length must be specified at the order iSYSTEM gives no assurance for BlueBox operation with this cable The cable i...

Page 11: ... Connected NC 3 4 DAP2 Optional 2nd Data pin I O I O DAP Data pin DAP1 5 6 DAPEN Optional 3rd Data pin I O Not Connected NC 7 8 Vref Reference voltage I Not Connected NC 9 10 nRESET Reset O Revision A1 10 pin ECU14 target pinout A2 The following pinout is valid on the target side Signal Direction Signal Description Signal Pin Pin Signal Signal Description Signal Direction Ground GND 1 2 DAP0 DAP c...

Page 12: ...d on the target side Signal Direction Signal Description Signal Pin Pin Signal Signal Description Signal Direction 1 2 Ground GND 3 4 DAP0 DAP clock O I O DAP Data pin DAP1 5 6 I O Power on Reset nRESET 7 8 nTRST DAPEN Optional 3rd Data pin I O I O Reference Voltage Vref 9 10 DAP2 Optional 2nd Data pin I O 10 pin MEDC17 target pinout Signal Direction is described from the BlueBox perspective The p...

Page 13: ...escription Signal Pin Pin Signal Signal Description Signal Direction Not Connected NC 1 2 Vref Reference Voltage I Not Connected NC 3 4 DAP0 DAP Clock O Ground GND 5 6 DAP1 DAP Data pin I O Not Connected NC 7 8 NC Not Connected Not Connected NC 9 10 DAP2 Optional 2nd Data pin I O Ground GND 11 12 nTRST JTAG O Not Connected NC 13 14 NC Not Connected Not Connected NC 15 16 NC Not Connected Ground GN...

Page 14: ... both Refer to winIDEA Help www isystem com groundingwire for more information 2 Connect the iC5700 Power Supply to the mains outlet and the iC5700 3 Connect the iC5700 to the PC via the supplied Ethernet or USB 3 0 cable 4 Connect the Active Probe to the iC5700 FNet Port through the supplied FNet Micro Cable If a cable longer than 1 0m is required for example when debugging an ECU in a vehicle or...

Page 15: ...ed 10 cm ribbon cables should be connected to the appropriately marked interface on the Active Probe Connecting procedure It is presumed that the two 10 pin 1 27mm ribbon cable s is are already connected to the Active Probe via the connector s with the shield Pin 1 markers and the red wire helps you denote the first position 1 Allocate the pin 1 position on the Target and on the 10 pin 1 27mm ribb...

Page 16: ...4 optional In case of DAPE connector repeat step 2 and 3 with the second cable ...

Page 17: ... voltage levels for the debug interface are configured within winIDEA via Hardware menu CPU Options Hardware When the microcontroller target supplies 5 0V to the Vref signal pin 1 use the radio button selection to select the Vref option instead ...

Page 18: ...ine default or DAP Wide a 3 pin DAP with two data lines Clock The DAP frequency must be configured with the frequency being entered in kHz DAPE Enable for simultaneous DAP and DAPE operation The Debug channel mode should be set appropriately from the drop down list options and as before valid clock frequencies for both interfaces should be entered in kHz When the DAPE interface is not in use ensur...

Page 19: ...y JTAG debug interface support is also available through a dedicated JTAG cable adapter e g IC50160 Infineon DAP DAPE Active Probe or Infineon AGBT Active Probe In order to switch from the default DTM interface and use to the Active Probe 1 Click Refresh in Hardware menu Options FNet Currently connected FNodes 2 Click Create configurations for connected FNodes Selected device is displayed in FNode...

Page 20: ...ve Probe If you have only one Active Probe connected you can leave the Active Probe selected and winIDEA will automatically connect to an available Active Probe If you have several Active Probes connected to your BlueBox select the desired Active Probe from the drop down menu ...

Page 21: ...ineon USB C Active Probe Infineon DAP DAPE Active Probe Accessories Ordering Code Description IA10PIN10PIN127 AP Set of two 10 pin 1 27mm 10cm long DAP interface ribbon cables IADAP10ECU14 ECU14 DAP 10 pin 1 27mm Converter IADAP10MEDC17 MEDC17 DAP 10 pin 1 27mm Converter IAPIN10SAM22TRICO RE ERF8 DAP 22 pin Adapter IA10PIN10P AP CUST 10 pin 1 27mm custom length DAP interface ribbon cable BB FNETMI...

Page 22: ...User Notes This page is intentionally left blank ...

Page 23: ...This page is intentionally left blank ...

Page 24: ... information provided in this document at the time of publishing Whilst iSYSTEM reserves the right to make changes to its products and or the specifications detailed herein it does not make any representations or commitments to update this document iSYSTEM All rights reserved ...