iSYSTEM, October 2016
50/69
To connect this cable adapter to the AMPMODU System 50 target connector, an additional adapter is included:
Nexus 50-pin AMPMODU System 50 target connector
Nexus 50-pin AMPMODU System 50 adapter
The following pinout is valid on the target side:
Signal direction
Signal
Pin
Pin
Signal
Signal direction
NC
1
2
NC
NC
3
4
NC
NC
5
6
NC
O
~RESET
7
8
VREF
O
~EVTI
9
10
NC
O
~RSTI
11
12
NC
O
~MSEI
13
14
NC
O
MDI0
15
16
NC
O
MCKI
17
18
GND
MDO0
19
20
GND
I
MCKO
21
22
GND
I
~EVTO
23
24
GND
I
~MSEO
25
26
VENDOR_IO1
I/O
I
MDO1
27
28
GND
I
MDO2
29
30
GND
I
MDO3
31
32
GND
O
MDI1
33
34
GND
NC
35
36
GND
I
MDO4
37
38
GND
I
MDO5
39
40
GND
I
MDO6
41
42
GND
I
MDO7
43
44
GND
NC
45
46
GND
NC
47
48
GND
I/O
VENDOR_IO2
49
50
GND
Nexus 50-pin AMPMODU System 50 target connector
Blue colored signals are required for trace.
The adapter connects to the target via a 50-pin AMPMODU System 50 connector (for example TE Connectivity:
5-104550-6). A target should feature a matching part (for example TE Connectivity: 5-104549-7).