6. Maintenance / Care / Disposal

The product is maintenance-free. It is sufficient from time to time to 
remove any dust deposits. This may only be done in a power-free 
state.

Disposal (European Union)
Do not dispose of product in household waste! Products with this 
symbol

7. Storage

The product must be stored in a dry place, protected from dirt and 
mechanical stress. After damp or dirty storage, the product may only 
be operated after a condition check by an authorised electrician. 

8. Assembly

(Only by certified electrician!)
Mount the product only when it is in a power-free state!
Switch off the power supply, check that there is no voltage, secure 
against being switched on again!
The device may only be operated at voltages according to the tech-
nical data and loaded with the currents defined therein. Only use 
suitable equipment (system modules).

Check that there are no loose parts in the product. If this is the case 
and the presence of such parts is not explicitly described, do not 
install or commission the product. 
Only use suitable cables and fixing screws. 

Assembly site
• The product can be installed in any position in a casing to be deter-

mined by the electrician (distribution box, switch cabinet). Observe 
maximum ambient temperature!

Assembly steps
(Read completely before assembly!) 
• Mount the device in a suitable casing. 
• Make the electrical connections according to the wiring diagram. 
• Configure the DIP switches according to your requirements.
• Only after a complete connection and a visual test by a qualified 

electrician, the system may be put under voltage.

Seebacher GmbH

Marktstrasse 57
83646 Bad Tölz
GERMANY

Phone: +49 (0) 80 41 / 77 77 6 
Fax: +49 (0) 80 41 / 77 77 2

www.seebacher.de
[email protected]

5. Service address

4. Declaration of Conformity

The valid declaration of conformity for the module can be requested 
from us free of charge by stating type and article no. as follows:
By phone: 

+49(0)8041/77776

By fax: 

+49(0)8041/77772

By mail: 

[email protected]

3. Warranty

We provide warranty within the framework of the statutory provisi-
ons. These are limited to the intended use of the module and refer 
to the repair or replacement of the ISYGLT module. Please send the 
device with an attached error description to our company address 
given below. 

must be disposed of according to the EU directive WEEE 2012/19/
EU on waste electrical and electronic equipment at the local collec-
tion points for waste electrical and electronic equipment!

Summary of Contents for DA-04-VX

Page 1: ...www seebacher de Tel 08041 77776 Marktstra e 57 83646 Bad T lz info seebacher de Fax 08041 77772 1 Technical Data Instruction Manual DA 04 VX Article no 80027003 Analog module with 4 analog outputs 0...

Page 2: ...over to the device operator The operator will store the documents so that they can be made available if necessary 1 2 Symbols used Observe the following safety and other instructions in the manual Ha...

Page 3: ...afety instructions Observe the following general safety instructions when installing and commissioning the device Assembly and installation of the ISYGLT module may only be carried out by a qualified...

Page 4: ...sembly site The product can be installed in any position in a casing to be deter mined by the electrician distribution box switch cabinet Observe maximum ambient temperature Assembly steps Read comple...

Page 5: ...o called OVERSAMPLING the DA module automatically corrects the jumps in the analog values caused by the cycle times of the BUS system For this purpose the analog values between the BUS cycles are tran...

Page 6: ...m DIN rail 3 HP 10 Technical data Type designation DA 04 VX Article no 80027003 Operating voltage 18V to 35V DC or 18V to 27V AC Current consumption max 120mA at 35V and full load of the outputs max 2...

Page 7: ...erating voltage 0V Operating voltage A Subnet BUS A RS 485 B Subnet BUS B RS 485 E Emergency operating input GND Reference potential ground for analog outputs 4x internally connected UA1 Analog output...

Page 8: ...230V AC Dimmer 1 10V 230V AC ECG dimmable 1 2 3 4 5 6 7 8 Address 4 analog outputs 0 10V 1 10V ISYGLT DA 04 VX Art Nr 80027003 Ub 0V BUS A BUS B UA1 GND UA2 GND UA3 GND UA4 GND E Attention If the emer...

Reviews: