3

The module is designed for cabinet installation on a 35mm DIN 
rail according to EN 60715 in corresponding standard housings. 
Extreme environmental conditions impair the function of the pro-
duct.

• 

Protect module from shocks

• 

Use module indoors only

• 

Protect module from humidity

In addition to these safety instructions, you must also observe 
the special safety instructions listed in the individual chapters for 
the individual acts.

2.4. Qualification of staff

Assembly, commissioning, operation, maintenance, decommis-
sioning and disposal may only be carried out by qualified staff. 
Work on electrical parts may only be carried out by a trained 
electrician in accordance with the applicable regulations and 
directives. Other activities in connection with the ISYGLT module, 
such as assembly and installation of system components with 
tested standard plug connections, as well as operation and con-
figuration of the ISYGLT module may only be carried out by trai-
ned staff.

2.5. Changes to the product 

Unauthorized modifications to the ISYGLT module which are not 
described in this or the other applicable instructions can lead to 
malfunctions and are prohibited for safety reasons.

2.6. Use of spare parts and additional equipment

The module may be damaged if unsuitable spare parts and addi-
tional equipment are used. Only use original spare parts and 
additional equipment from the manufacturer.

2.7. Liability notes

SEEBACHER accepts no liability or warranty whatsoever for 
damage and consequential damage caused by non-compliance 
with the technical regulations, instructions and recommendati-
ons. SEEBACHER shall not be liable for any costs or damage 
incurred by the user or third parties as a result of the use of this 
equipment, in particular improper use of the equipment, misuse 
or malfunction of the connection, malfunction of the equipment 
or connected devices. 

SEEBACHER accepts no liability for printing errors.

2. Safety instructions

Observe the following general safety instructions when installing 
and commissioning the device:

Assembly and installation of the ISYGLT module may only be carried 
out by a qualified electrician. Other activities in connection with the 
ISYGLT module, such as assembly and installation of system com-
ponents with tested standard plug connections, as well as operation 
and configuration of the ISYGLT module may only be carried out by 
trained staff.

Observe the electrical installation regulations of the country in which 
the device is installed and operated as well as its national accident 
prevention regulations. In addition, observe internal company regu-
lations (work, operating and safety regulations).

Before working on the ISYGLT module system, it must be 
disconnected from the power supply and secured against 
being switched on again. After completion of the assembly, 
installation and maintenance work, an electrical check must 
be carried out! Check all protective conductor connections 
and the voltages at all connection plugs as well as at each 
individual module slot.

2.1. Intended usage 

The module is exclusively suitable for regulation (control) in con-
nection with ISYGLT system components. Any other use is not 
intended. The limit values stated in the technical data must not be 
exceeded under any circumstances. This applies in particular to 
the permissible ambient temperature range and the permissible 
IP protection type. For applications with a higher required IP pro-
tection type, the ISYGLT module must be installed in a housing 
or a cabinet with a higher IP protection type.

2.2. Predictable mishandling

The module must not be used in the following cases in particular: 

 explosive area 

When operating in explosive areas, sparking can lead to defla-
gration, fire or explosions.

2.3. Safe handling

This module corresponds to the state of the art and the recog-
nised safety regulations. Each device is tested for function and 
safety before delivery.

Only operate this module in perfect condition in accordance with 
the operating instructions, the applicable regulations and directi-
ves of the country in which the device is installed and operated, 
and the applicable safety and accident prevention regulations.

Summary of Contents for DA-04-VX

Page 1: ...www seebacher de Tel 08041 77776 Marktstra e 57 83646 Bad T lz info seebacher de Fax 08041 77772 1 Technical Data Instruction Manual DA 04 VX Article no 80027003 Analog module with 4 analog outputs 0...

Page 2: ...over to the device operator The operator will store the documents so that they can be made available if necessary 1 2 Symbols used Observe the following safety and other instructions in the manual Ha...

Page 3: ...afety instructions Observe the following general safety instructions when installing and commissioning the device Assembly and installation of the ISYGLT module may only be carried out by a qualified...

Page 4: ...sembly site The product can be installed in any position in a casing to be deter mined by the electrician distribution box switch cabinet Observe maximum ambient temperature Assembly steps Read comple...

Page 5: ...o called OVERSAMPLING the DA module automatically corrects the jumps in the analog values caused by the cycle times of the BUS system For this purpose the analog values between the BUS cycles are tran...

Page 6: ...m DIN rail 3 HP 10 Technical data Type designation DA 04 VX Article no 80027003 Operating voltage 18V to 35V DC or 18V to 27V AC Current consumption max 120mA at 35V and full load of the outputs max 2...

Page 7: ...erating voltage 0V Operating voltage A Subnet BUS A RS 485 B Subnet BUS B RS 485 E Emergency operating input GND Reference potential ground for analog outputs 4x internally connected UA1 Analog output...

Page 8: ...230V AC Dimmer 1 10V 230V AC ECG dimmable 1 2 3 4 5 6 7 8 Address 4 analog outputs 0 10V 1 10V ISYGLT DA 04 VX Art Nr 80027003 Ub 0V BUS A BUS B UA1 GND UA2 GND UA3 GND UA4 GND E Attention If the emer...

Reviews: