Reading Data stored In memory Ramdomly: 
On read Status ,Press the "SAMPLE" Key and enter the 
number of the record in questions and press "ENTER" 
Key then the desired data will be displayed Press "
RESET"  Key to exit  As shown in following figure:

.In instantaneous data storage mode, you should 

    first press "SAMPLE" Key and input "0" second ,
    then press "ENTER" to finish the rate set up. 
b.Press the "REC" Key to finish the recording, 
   otherwise the recording will be invalid. 
c.The maximum number of readings can be stored 500.
d.If your reading number is bigger than the total 
    quantity of data stored in memory ,the LCD will 
    shows the last stored. 

Note :
a

Clearing the Stored data: 
Press down the "CLEAR" Key for 5 seconds then
CRL appears on the LCDindicating , all the stored 
data being Cleared.  As shown in following figure: 

Connection With Pc 

1). Requirement of computer configuration: 
      CPU : Pentium 600MHZ Or above ;
      One free available USB Connecting Interface; 
      The lowest screen resolution of monitor is 800*600 (
      or much higher ),color mode; 
      At least 8MB available memory; 
      At least 50MB available disk memory; 
      Operation system : MICROSOFT WINDOWS 98/ME/
       2000/XP HOME/XP PROFESSIONAL 32BIT 

2). Install the software from the disc:
      Place the attached Disc in your disc driver open the 
      disc driver plate symbol , double click the "
      Anemometer setup .exe " .To enter into Program 
      installation window, click "NEXT" , as show in 
      following figure: 

Summary of Contents for GM8902

Page 1: ...Version 8902 EN 0 AIR FLOW ANEMOMETER INSTRUCTION MANUAL FLOW CMM M 2...

Page 2: ...ith PC 09 11 13 14 16 17 19 CONTENTS 1 Before Use 2 Operation 3 Other Items Thank you for purchasing our Air Flow Anemometer Carefully unpack your kit and ensure that you have the following Items In c...

Page 3: ...Unit conversion of wind velocity temperature and flow Measurement of maximum and minimum wind velocity Measurement of 2 3 Vmax and average wind flow Data holding storing and deleting function Low bat...

Page 4: ...rature in metric FLOW 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 19 18 20 21 22 27 26 25 24 23 FT 2 1 USB interface 2 LCD display 3 ON OFF key 4 Data holding key 5 Unit transform key 6 Backlight on off...

Page 5: ...data symbol 25 2 3 of maximum value measurement one of the wind flow measuring method 26 Showing minimum values 27 When measuring average values one of the wind flow measuring Method this symbol appe...

Page 6: ...y Temperature Temperature Humidity Measurement of Wind Velocity and Temperature Press The key all the symbols will be shown on the screen for 1 second then the unit goes into current wind velocity and...

Page 7: ...e Measurement 1 Small Vanes pattern will showing along with the display of TEMP symbol 2 Press button or number 6 key to Switch Duct area Measurement of Windflow If the area value has been set before...

Page 8: ...t area to measure current wind flow value right away As shown in following figure Aim the vane of the attached unit at duct area properly take measurement of 2 3 V max wind flow right away press again...

Page 9: ...ill show serial number in the meantime you can take measurement of the first group wind flow values As shown in following figure Then select another test point press the NEXT key to take measurement o...

Page 10: ...r VEL state set the sampling rate 0 by pressing SAMPLE key and in put a 0 sampling time and then press ENTER Now each time REC is pressed the present reading will be stored 2 Automatic data storage un...

Page 11: ...ry the LCD will shows the last stored Note a Clearing the Stored data Press down the CLEAR Key for 5 seconds then CRL appears on the LCDindicating all the stored data being Cleared As shown in followi...

Page 12: ...ction as shown in following figure File menu bar Option menu bar Helpmenu bar 3 Software interface Menu Bar 20 21 NOTE 1 Double click the software shortcut on the desktop to start from menu the route...

Page 13: ...l time as shown on the computer Open measurement data file that is saved as the LAB format Save real time measurement data Import data stored in the anemometer to computer Export the saved data to Exc...

Page 14: ...ack If the unit connect with PC LCD will display symbol If the unit dis connect with PC symbol will not shown Button Function Click to start real time measurement Click to stop real time measurement C...

Page 15: ...f the unit is not working properly 1 Screen is blank Check the battery is inserted correctly Open the bat tery door on the bottom rear of the unit The symbols on the battery should match the corres po...

Page 16: ...or thinner to clean the unit casing which will especially erode the LCD surface just clean the unit lightly as needed with little clean water Never impact the unit or use on humidity condition Do not...

Reviews: